Accuracy of heart rate measurement using AirPods Pro 3 during graded treadmill exercise: A laboratory-based validation study
PLOS Digital Health · 30.04.2026 · 5 (4) · e0001373
DOI: 10.1371/journal.pdig.0001373 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS Digital Health, online erschienen am 30.04.2026. Verfasst von Cailbhe Doherty und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Public Health, Physiotherapy and Sports Science, University College Dublin, Dublin, Ireland. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Health Research Board.
Abstract (Originalsprache)
AirPods Pro 3 incorporate an in-ear optical heart-rate sensor, but independent validation during exercise is limited. We evaluated agreement between AirPods Pro 3 heart rate and an ECG-derived chest-strap reference (Polar H10) during graded treadmill exercise in a controlled laboratory setting. Forty adults (mean age 23·8 years; 37·5% female) completed a protocol comprising rest and progressive exercise stages targeting ~40–85% of age-predicted maximal heart rate, including rapid workload transitions. Heart-rate time series from both devices were synchronised by timestamp and aggregated into non-overlapping 5-s epochs. Agreement was assessed using a repeated-measures Bland–Altman approach implemented via a linear mixed-effects model with participant-level random effects; absolute error metrics were calculated at the participant level and summarised overall and by intensity category. Across 16,735 paired epochs, mean bias was −0·03 beats·min ⁻ ¹ (AirPods Pro 3 minus Polar H10; 95% CI −0·22 to 0·17), indicating negligible systematic error. The total standard deviation of differences was 5·23 beats·min ⁻ ¹, yielding 95% limits of agreement from −10·27 to 10·22 beats·min ⁻ ¹, with greater dispersion at higher heart rates. Overall mean absolute error was 2·08 beats·min ⁻ ¹ and mean absolute percentage error was 2·02%, with mean absolute error ranging from 1·31 to 2·4 beats·min ⁻ ¹ across intensity categories. AirPods Pro 3 therefore provided heart-rate estimates closely aligned with a validated chest-worn reference during graded treadmill exercise in healthy adults, with minimal bias and low average error but wider epoch-to-epoch variability at higher intensities.
Autor:innen und Institutionen
- School of Public Health, Physiotherapy and Sports Science, University College Dublin, Dublin, Ireland.
- Insight Research Ireland Centre for Data Analytics, University College Dublin, Dublin, Ireland.
- Cardiology, Beacon Hospital, Dublin, Ireland.
- School of Medicine, University College Dublin, Dublin, Ireland.
ORCID-Profile: Cailbhe Doherty
Förderung
- Health Research Board
Zitieren
APA
Doherty, C., Burke, D., Mitchell, O., Lawless, D., Brar, J., Fuchs, M., & Lambe, R. (2026). Accuracy of heart rate measurement using AirPods Pro 3 during graded treadmill exercise: A laboratory-based validation study. PLOS Digital Health, 5(4), e0001373. https://doi.org/10.1371/journal.pdig.0001373
Vancouver
Doherty C, Burke D, Mitchell O, Lawless D, Brar J, Fuchs M, et al. Accuracy of heart rate measurement using AirPods Pro 3 during graded treadmill exercise: A laboratory-based validation study. PLOS Digital Health. 2026;5(4):e0001373. doi:10.1371/journal.pdig.0001373
BibTeX
@article{Doherty2026,
author = {Doherty, Cailbhe and Burke, David and Mitchell, Owen and Lawless, David and Brar, Jasman and Fuchs, Michael and Lambe, Rory},
title = {Accuracy of heart rate measurement using AirPods Pro 3 during graded treadmill exercise: A laboratory-based validation study},
journal = {PLOS Digital Health},
year = {2026},
volume = {5},
number = {4},
pages = {e0001373},
doi = {10.1371/journal.pdig.0001373}
}
EUVIMED