Validation of Wearable Digital Devices for Heart Rate Measurement During Exercise Test in Patients With Coronary Artery Disease

Chul Kim, Jun Hyeong Song, Seung Hyoun Kim

Annals of Rehabilitation Medicine · 31.08.2023 · 47 (4) · 261-271

DOI: 10.5535/arm.23019 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Rehabilitation Medicine, erschienen am 31.08.2023. Verfasst von Chul Kim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Medicine, Inje University Sanggye Paik Hospital, Inje University College of Medicine, Seoul, Korea. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To assess the accuracy of recently commercialized wearable devices in heart rate (HR) measurement during cardiopulmonary exercise test (CPX) under gradual increase in exercise intensity, while wearable devices with HR monitors are reported to be less accurate in different exercise intensities.

Methods

CPX was performed for patients with coronary artery disease (CAD). Twelve lead electrocardiograph (ECG) was the gold standard and Apple watch 7 (AW7), Galaxy watch 4 (GW4) and Bio Patch Mobicare 200 (MC200) were applied for comparison. Paired absolute difference (PAD), mean absolute percentage error (MAPE) and intraclass correlation coefficient (ICC) were evaluated for each device.

Results

Forty-four participants with CAD were included. All the devices showed MAPE under 2% and ICC above 0.9 in rest, exercise and recovery phases (MC200=0.999, GW4=0.997, AW7=0.998). When comparing exercise and recovery phase, PAD of MC200 and AW7 in recovery phase were significantly bigger than PAD of exercise phase (p

Schlagwörter

Stichwörter der Autor:innen

Cardiac rehabilitationExercise testHeart rateWearable electronic devices

Autor:innen und Institutionen

  • Department of Rehabilitation Medicine, Inje University Sanggye Paik Hospital, Inje University College of Medicine, Seoul, Korea.

Zitieren

APA

Kim, C., Song, J. H., & Kim, S. H. (2023). Validation of Wearable Digital Devices for Heart Rate Measurement During Exercise Test in Patients With Coronary Artery Disease. Annals of Rehabilitation Medicine, 47(4), 261-271. https://doi.org/10.5535/arm.23019

Vancouver

Kim C, Song JH, Kim SH. Validation of Wearable Digital Devices for Heart Rate Measurement During Exercise Test in Patients With Coronary Artery Disease. Annals of Rehabilitation Medicine. 2023;47(4):261-271. doi:10.5535/arm.23019

BibTeX
@article{Kim2023,
  author = {Kim, Chul and Song, Jun Hyeong and Kim, Seung Hyoun},
  title = {Validation of Wearable Digital Devices for Heart Rate Measurement During Exercise Test in Patients With Coronary Artery Disease},
  journal = {Annals of Rehabilitation Medicine},
  year = {2023},
  volume = {47},
  number = {4},
  pages = {261--271},
  doi = {10.5535/arm.23019}
}
Kostenlos starten →