Validation of Wearable Digital Devices for Heart Rate Measurement During Exercise Test in Patients With Coronary Artery Disease
Annals of Rehabilitation Medicine · 31.08.2023 · 47 (4) · 261-271
DOI: 10.5535/arm.23019 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Rehabilitation Medicine, erschienen am 31.08.2023. Verfasst von Chul Kim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Medicine, Inje University Sanggye Paik Hospital, Inje University College of Medicine, Seoul, Korea. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objective
To assess the accuracy of recently commercialized wearable devices in heart rate (HR) measurement during cardiopulmonary exercise test (CPX) under gradual increase in exercise intensity, while wearable devices with HR monitors are reported to be less accurate in different exercise intensities.
Methods
CPX was performed for patients with coronary artery disease (CAD). Twelve lead electrocardiograph (ECG) was the gold standard and Apple watch 7 (AW7), Galaxy watch 4 (GW4) and Bio Patch Mobicare 200 (MC200) were applied for comparison. Paired absolute difference (PAD), mean absolute percentage error (MAPE) and intraclass correlation coefficient (ICC) were evaluated for each device.
Results
Forty-four participants with CAD were included. All the devices showed MAPE under 2% and ICC above 0.9 in rest, exercise and recovery phases (MC200=0.999, GW4=0.997, AW7=0.998). When comparing exercise and recovery phase, PAD of MC200 and AW7 in recovery phase were significantly bigger than PAD of exercise phase (p
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Rehabilitation Medicine, Inje University Sanggye Paik Hospital, Inje University College of Medicine, Seoul, Korea.
Zitieren
APA
Kim, C., Song, J. H., & Kim, S. H. (2023). Validation of Wearable Digital Devices for Heart Rate Measurement During Exercise Test in Patients With Coronary Artery Disease. Annals of Rehabilitation Medicine, 47(4), 261-271. https://doi.org/10.5535/arm.23019
Vancouver
Kim C, Song JH, Kim SH. Validation of Wearable Digital Devices for Heart Rate Measurement During Exercise Test in Patients With Coronary Artery Disease. Annals of Rehabilitation Medicine. 2023;47(4):261-271. doi:10.5535/arm.23019
BibTeX
@article{Kim2023,
author = {Kim, Chul and Song, Jun Hyeong and Kim, Seung Hyoun},
title = {Validation of Wearable Digital Devices for Heart Rate Measurement During Exercise Test in Patients With Coronary Artery Disease},
journal = {Annals of Rehabilitation Medicine},
year = {2023},
volume = {47},
number = {4},
pages = {261--271},
doi = {10.5535/arm.23019}
}
EUVIMED