EUVIMEDEUVIMED entdecken
Crossref

Intra-rater reliability of rehabilitative ultrasound imaging of the cervical multifidus muscle in healthy subjects

Beata Czechowska, Katarzyna Gilbov, Marcin Świątczak

Physiotherapy Review · 2021

DOI: 10.5114/for.2021.106948 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiotherapy Review, 2021. Verfasst von Beata Czechowska und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The multifidus muscle is a deep muscle and the main stabiliser of the spine.Abnormal activity and morphology of this muscle can provoke cervical spinal pain.One way to assess the morphology of deep stabilising muscles is ultrasonography.There is limited evidence on the reliability of measuring the multifidus muscle in the cervical region of the spine using rehabilitative ultrasound imaging (RUSI).

Aims

This study aimed to evaluate the reliability of measuring the cross-sectional area, surface area, and circumference of the multifidus muscle in the cervical region of the spine Material and methods:The study involved 10 healthy subjects, including 7 women and 3 men, aged 23-62 years.The cross-sectional area, circumference, and surface area of the multifidus muscle in the cervical section of the spine were measured in the subjects using RUSI.The intraclass correlation coefficient (ICC) was used for each measurement (3.1-3.3) as recommended index for the intra-rater reliability assessment.

Results

Taking measurements twice, with a 15-minute interval between them, increased the reliability of measurements of the cross-sectio-nal area, surface area, and circumference of the multifidus muscle in the cervical section of the spine to ICC > 0.9, which indicates excellent reliability.The mean of the three measurements decreased the ICC value to 0.8-0.9,showing good reliability of the measurements.The ICC 3.3 values for measurements of the area and circumference of the multifidus muscle in the cervical region of the spine performed after seven days were lower, in the range of 0.48-0.55,which suggests questionable reliability of measurements.The value of ICC 3.3 of the cross-sectional area also decreased, although it remained in the upper limit (0.85), demonstrating good reliability of the measurement. Conclusions:The RUSI is a reliable tool for assessing the morphology of the multifidus muscle in the cervical spine region.

Zitieren

APA

Czechowska, B., Gilbov, K., & Świątczak, M. (2021). Intra-rater reliability of rehabilitative ultrasound imaging of the cervical multifidus muscle in healthy subjects. Physiotherapy Review. https://doi.org/10.5114/for.2021.106948

Vancouver

Czechowska B, Gilbov K, Świątczak M. Intra-rater reliability of rehabilitative ultrasound imaging of the cervical multifidus muscle in healthy subjects. Physiotherapy Review. 2021. doi:10.5114/for.2021.106948

BibTeX
@article{Czechowska2021,
  author = {Czechowska, Beata and Gilbov, Katarzyna and Świątczak, Marcin},
  title = {Intra-rater reliability of rehabilitative ultrasound imaging of the cervical multifidus muscle in healthy subjects},
  journal = {Physiotherapy Review},
  year = {2021},
  doi = {10.5114/for.2021.106948}
}
Kostenlos starten →