Fachartikel in der Zeitschrift BMC Musculoskeletal Disorders, online erschienen am 15.11.2024. Verfasst von Martin Bjørn Stausholm und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Global Public Health and Primary Care, University of Bergen, Bergen, Hordaland, Norway. m.b.stausholm@gmail.com. Hauptthemen laut MEDLINE: Quadriceps Muscle, Ultrasonography, Observer Variation. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Bergen.
Abstract (Originalsprache)
Background
The rectus femoris muscle plays an important role in maintaining lower limb stability and biomechanical control during basic physical activities. Both reduced quadriceps strength and decreased muscle thickness of the rectus femoris, as measured by ultrasound, are associated with an increased risk of falls in older adults. We estimated the relative and absolute intra-rater, inter-rater, and inter-day reliability of the procedure.
Methods
A female biologist and a male physical educator, both holding a master’s degree in human movement and rehabilitation, captured ultrasound images of the right rectus femoris muscle in 106 healthy participants (58 females and 48 males), aged 18 to 73 years. Each rater captured three images per participant during each visit, with two visits 7 to 10 days apart. A third person subsequently measured the muscle thickness. We calculated the Intraclass Correlation Coefficients (ICC) using a two-way random model and determined the 95% minimal detectable difference (MDD).
Results
The mean muscle thickness was 2.12 cm. The reliability based on single measurements was as follows: the intra-rater ICC for raters A and B was 0.998 at both visits (MDDs: 0.074–0.082 cm). The inter-rater ICC was 0.976 at visit 1 and 0.977 at visit 2 (MDDs: 0.269–0.270 cm). The inter-day ICC was 0.973 for rater A and 0.972 for rater B (MDDs: 0.286–0.291 cm). Sensitivity analyses accounting for age, sex, and the use of mean measurements produced similar results. The results were homoscedastic.
Conclusions
The rectus femoris muscle thickness was measured with good reliability using ultrasonography across all the settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Global Public Health and Primary Care, University of Bergen, Bergen, Hordaland, Norway. m.b.stausholm@gmail.com.
- Laboratory of Biophotonics and Experimental Therapeutics, Universidade Evangélica de Goiás, UniEvangelica. Av. Universitária Km 3,5, Anápolis, Goiás, Brazil.
- Integrated Laboratory of Neurosciences and Physical Conditioning, Universidade Evangélica de Goiás, UniEvangelica. Av. Universitária Km 3,5, Anápolis, Goiás, Brazil.
- Department of Global Public Health and Primary Care, University of Bergen, Bergen, Hordaland, Norway.
- Laboratório de Tecnologias em Saúde, Universidade Evangélica de Goiás, UniEvangelica. Av. Universitária Km 3,5, Anápolis, Goiás, Brazil.
- Post-Graduate Program in Bioengineering, Universidade Brasil, Av. Carolina Fonseca 236, Itaquera, São Paulo, Brazil.
ORCID-Profile: Martin Bjørn Stausholm, Katielle Rodrigues da Silva, Pedro Augusto Inácio, Alberto Souza de Sá Filho, Pedro Sardinha Leonardo Lopes-Martins, Jan Magnus Bjordal, Patrícia Sardinha Leonardo, Rodrigo Alvaro B Lopes-Martins
Förderung
- University of Bergen
Zitieren
APA
Stausholm, M. B., da Silva, K. R., Inácio, P. A., de Sá Filho, A. S., Lopes-Martins, P. S. L., Bjordal, J. M., Leonardo, P. S., & Lopes-Martins, R. A. B. (2024). Reliability of ultrasound assessment of the rectus femoris muscle thickness: intra-rater, inter-rater, and inter-day analysis accounting for age and sex. BMC Musculoskeletal Disorders, 25(1). https://doi.org/10.1186/s12891-024-08033-5
Vancouver
Stausholm MB, da Silva KR, Inácio PA, de Sá Filho AS, Lopes-Martins PSL, Bjordal JM, et al. Reliability of ultrasound assessment of the rectus femoris muscle thickness: intra-rater, inter-rater, and inter-day analysis accounting for age and sex. BMC Musculoskeletal Disorders. 2024;25(1). doi:10.1186/s12891-024-08033-5
BibTeX
@article{Stausholm2024,
author = {Stausholm, Martin Bjørn and da Silva, Katielle Rodrigues and Inácio, Pedro Augusto and de Sá Filho, Alberto Souza and Lopes-Martins, Pedro Sardinha Leonardo and Bjordal, Jan Magnus and Leonardo, Patrícia Sardinha and Lopes-Martins, Rodrigo Alvaro B},
title = {Reliability of ultrasound assessment of the rectus femoris muscle thickness: intra-rater, inter-rater, and inter-day analysis accounting for age and sex},
journal = {BMC Musculoskeletal Disorders},
year = {2024},
volume = {25},
number = {1},
doi = {10.1186/s12891-024-08033-5}
}
EUVIMED