EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Intra- and inter-rater reliability of ultrasound assessment of rectus femoris muscle thickness by physiotherapists: influence of operator experience

Daniele Conte, Giulia Costantini, Chiara Pinzini, Giuliana De Maio, Maria Parpinel, Daniele Vidi

Journal of Bodywork and Movement Therapies · 2026-10 · 48 · 1045-1050

DOI: 10.1016/j.jbmt.2026.08.020 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Bodywork and Movement Therapies, 2026-10. Verfasst von Daniele Conte und 5 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Social Fund, Regione Autonoma Friuli Venezia Giulia.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Rehabilitative ultrasound imaging is increasingly used in physiotherapy as an objective method for muscle assessment. However, its reliability across different levels of operator experience requires further clarification.

Objective

To evaluate the intra- and inter-rater reliability of rectus femoris thickness measurements among expert and novice physiotherapists.

Methods

Four physiotherapists (two experts, two novices) assessed rectus femoris thickness in healthy individuals. Reliability was evaluated using intraclass correlation coefficients (ICC) and limits of agreement (LoA). The standard error of measurement (SEM) and minimal detectable change (MDC) were calculated to quantify measurement precision.

Results

Both expert raters demonstrated good-to-excellent intra-rater reliability (Rater A: ICC 2 , 1 0.84–0.98; Rater B: ICC 2 , 1 0.81–0.98). Novice raters showed good-to-excellent (Rater C: ICC 2 , 1 0.80–0.98) and moderate-to-excellent reliability (Rater D: ICC 2 , 1 0.73–0.97). The pooled SEM was 0.48 mm, with no clinically relevant differences between raters. The MDC was 1.34 mm. Inter-rater reliability was moderate-to-good for single measurements and good-to-excellent for average measurements, with similar patterns across expertise groups. LoA ranged from –3.13 to 3.05 mm for experts and from –3.25 to 2.09 mm for novices.

Conclusions

Ultrasound assessment of rectus femoris thickness demonstrates high intra-rater reliability among physiotherapists, supporting its use in clinical practice. Our preliminary findings suggest that novice raters may approach expert-level reliability following a short training protocol. Inter-rater reliability was acceptable and improved when averaging multiple measurements. For longitudinal monitoring, assessments are likely to be more consistent when performed by the same operator; when this is not feasible, averaging repeated measurements may help reduce inter-operator variability.

Förderung

  • European Social Fund
  • Regione Autonoma Friuli Venezia Giulia

Zitieren

APA

Conte, D., Costantini, G., Pinzini, C., Maio, G. D., Parpinel, M., & Vidi, D. (2026). Intra- and inter-rater reliability of ultrasound assessment of rectus femoris muscle thickness by physiotherapists: influence of operator experience. Journal of Bodywork and Movement Therapies, 48, 1045-1050. https://doi.org/10.1016/j.jbmt.2026.08.020

Vancouver

Conte D, Costantini G, Pinzini C, Maio GD, Parpinel M, Vidi D. Intra- and inter-rater reliability of ultrasound assessment of rectus femoris muscle thickness by physiotherapists: influence of operator experience. Journal of Bodywork and Movement Therapies. 2026;48:1045-1050. doi:10.1016/j.jbmt.2026.08.020

BibTeX
@article{Conte2026,
  author = {Conte, Daniele and Costantini, Giulia and Pinzini, Chiara and Maio, Giuliana De and Parpinel, Maria and Vidi, Daniele},
  title = {Intra- and inter-rater reliability of ultrasound assessment of rectus femoris muscle thickness by physiotherapists: influence of operator experience},
  journal = {Journal of Bodywork and Movement Therapies},
  year = {2026},
  volume = {48},
  pages = {1045--1050},
  doi = {10.1016/j.jbmt.2026.08.020}
}
Kostenlos starten →