EUVIMEDObjevte EUVIMED
Crossref

Assessment of Surface Roughness and Early Bacterial Adhesion on Machined, SLA, Anodized, and Laser-Modified Titanium Implant Surfaces: An In-Vitro Study

Anas Abdul Khader

Journal of Pioneering Medical Sciences · 2026-04-15 · 15 (S01) · 94-98

DOI: 10.47310/jpms202515s0119 ↗

At a glance

Journal article in Journal of Pioneering Medical Sciences, published online on 2026-04-15. Written by Anas Abdul Khader.

AbstraktBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Implant surface characteristics influence both osseointegration and early microbial colonization. The present in-vitro study compared machined, sandblasted and acid-etched (SLA), anodized, and laser-modified titanium surfaces to determine how different modification protocols affect roughness and 24-hour bacterial adhesion.

Methods

Eighty commercially pure titanium grade 4 discs were randomly allocated to four groups (n=20 each): machined, SLA, anodized, and laser-modified. Surface characterization was performed using optical profilometry (Ra, Rz, Rq, Rsk, and Rku) and scanning electron microscopy. Early bacterial adhesion at 24 hours was assessed using Streptococcus mutans under aerobic conditions and Porphyromonas gingivalis under anaerobic conditions. Colony-forming units (CFU/mm²) and fluorescence microscopy coverage percentages quantified adhesion. One-way ANOVA, Tukey post-hoc testing, and Pearson correlation analysis were applied at a significance level of p<0.05.

Results

SLA surfaces exhibited the highest roughness (Ra 2.34 ± 0.28 μm), followed by laser-modified (1.87 ± 0.23 μm), anodized (1.12 ± 0.18 μm), and machined surfaces (0.43 ± 0.09 μm) (p<0.001). SLA also showed the greatest bacterial adhesion. Compared with SLA, laser-modified surfaces demonstrated approximately 38.2% lower S. mutans counts and 38.8% lower P. gingivalis counts despite remaining moderately rough. Strong positive correlations were observed between Ra and bacterial adhesion parameters (r=0.80-0.85; p<0.001).

Conclusion

Surface modification protocols significantly influence both roughness and early bacterial adhesion on titanium. Within the limitations of this 24-hour single-species in-vitro model, laser-modified surfaces showed a favorable balance between moderate roughness and lower bacterial adhesion than SLA surfaces, and therefore appear promising rather than definitive for future implant surface design.

Cite

APA

Khader, A. A. (2026). Assessment of Surface Roughness and Early Bacterial Adhesion on Machined, SLA, Anodized, and Laser-Modified Titanium Implant Surfaces: An In-Vitro Study. Journal of Pioneering Medical Sciences, 15(S01), 94-98. https://doi.org/10.47310/jpms202515s0119

Vancouver

Khader AA. Assessment of Surface Roughness and Early Bacterial Adhesion on Machined, SLA, Anodized, and Laser-Modified Titanium Implant Surfaces: An In-Vitro Study. Journal of Pioneering Medical Sciences. 2026;15(S01):94-98. doi:10.47310/jpms202515s0119

BibTeX
@article{Khader2026,
  author = {Khader, Anas Abdul},
  title = {Assessment of Surface Roughness and Early Bacterial Adhesion on Machined, SLA, Anodized, and Laser-Modified Titanium Implant Surfaces: An In-Vitro Study},
  journal = {Journal of Pioneering Medical Sciences},
  year = {2026},
  volume = {15},
  number = {S01},
  pages = {94--98},
  doi = {10.47310/jpms202515s0119}
}