EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Bacterial Adhesion on Direct Metal Laser Sintering Titanium, Zirconia, and Polyether Ether Ketone Dental Implant Abutments: An In vitro Study

Lisa Vincent, Kavitha Janardanan, A. Maya Nandkumar, Harsha Kumar Karunakaran, Ravichandran Rajagopal, Prasanth Viswambharan

Journal of Interdisciplinary Dentistry · 2026-01 · 16 (1) · 45-54

DOI: 10.4103/jid.jid_101_24 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Interdisciplinary Dentistry, online erschienen am 30.04.2026. Verfasst von Lisa Vincent und 5 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Microbial adhesion on dental implant abutment can compromise the soft-tissue seal and result in periimplant infection. The aim of the present study is to compare the adherence of Streptococcus mutans , Streptococcus sanguinis , and Escherichia coli on the surface of direct metal laser sintering (DMLS) titanium, zirconia, and polyether ether ketone (PEEK) dental implant abutment materials. Settings: The study was conducted in the Department of Prosthodontics and Crown and Bridge, Government Dental College, Thiruvananthapuram.

Design

The study design was in-vitro observational study. Materials and Methods: Disks of 2 mm thickness and 8 mm diameter of each material were placed in trypticase soy broth inoculated with E. coli and brain heart infusion broth inoculated with S. mutans and S. sanguinis , and incubated at 37°C for 72 h under agitation mode. The microorganisms adhered to the samples were extracted and plated for viable count. Surface roughness was evaluated using a profilometer, and average surface average roughness was estimated for each of the materials. The contact angle of each disk was computed. Statistical Analysis Used: One-way analysis of variance test ( F -test) and Scheffe multiple comparisons ( post hoc test) were carried out to compare quantitative parameters.

Results

There was a statistically significant increase in the mean bacterial adherence of S. mutans in Zirconia (13.1 ± 4.8) as compared to PEEK (5.5 ± 0.5) ( P < 0.05). S. sanguinis in DMLS Titanium (11.4 ± 0.9) and E. coli in PEEK. Titanium exhibited the highest surface roughness and contact angle.

Conclusions

Bacterial adhesion on DMLS titanium, zirconia, and PEEK presented varied results depending on the organisms tested. S. sanguinis adhered more to DMLS titanium and S. mutans showed more affinity toward zirconia, and E. coli adhered more to PEEK. Although DMLS titanium showed the highest surface roughness and contact angle, no significant correlation between surface characteristics and bacterial adhesion could be drawn.

Zitieren

APA

Vincent, L., Janardanan, K., Nandkumar, A. M., Karunakaran, H. K., Rajagopal, R., & Viswambharan, P. (2026). Bacterial Adhesion on Direct Metal Laser Sintering Titanium, Zirconia, and Polyether Ether Ketone Dental Implant Abutments: An In vitro Study. Journal of Interdisciplinary Dentistry, 16(1), 45-54. https://doi.org/10.4103/jid.jid_101_24

Vancouver

Vincent L, Janardanan K, Nandkumar AM, Karunakaran HK, Rajagopal R, Viswambharan P. Bacterial Adhesion on Direct Metal Laser Sintering Titanium, Zirconia, and Polyether Ether Ketone Dental Implant Abutments: An In vitro Study. Journal of Interdisciplinary Dentistry. 2026;16(1):45-54. doi:10.4103/jid.jid_101_24

BibTeX
@article{Vincent2026,
  author = {Vincent, Lisa and Janardanan, Kavitha and Nandkumar, A. Maya and Karunakaran, Harsha Kumar and Rajagopal, Ravichandran and Viswambharan, Prasanth},
  title = {Bacterial Adhesion on Direct Metal Laser Sintering Titanium, Zirconia, and Polyether Ether Ketone Dental Implant Abutments: An In vitro Study},
  journal = {Journal of Interdisciplinary Dentistry},
  year = {2026},
  volume = {16},
  number = {1},
  pages = {45--54},
  doi = {10.4103/jid.jid_101_24}
}
Kostenlos starten →