Do Oral Hygiene Methods Alter Titanium Implant Surfaces? An In Vitro Surface Roughness Analysis
International Journal of Dental Hygiene · 29.10.2026
DOI: 10.1111/idh.70186 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Dental Hygiene, online erschienen am 29.10.2026. Verfasst von Vaishnavi Pandey und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Periodontology, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, India. Die Arbeit nennt 35 Literaturangaben.
Themen: Mundpflege
Abstract (Originalsprache)
Objectives
This study evaluated and compared the effects of three simulated daily oral hygiene regimens on the surface roughness ( R a ) of titanium alloy ( Ti6Al4V ) discs.
Methods
Twenty‐four Ti6Al4V discs were allocated to two groups based on baseline surface characteristics ( n = 12/group): Group 1 (Polished) and Group 2 (Sandblasted). Each was subdivided into three 30‐day regimens ( n = 4/regimen): Regimen A (Chemical only: 0.2% chlorhexidine digluconate (CHX) mouthrinse immersion), Regimen B (Combined electric toothbrushing [ETb] + fluoridated toothpaste [TP] + CHX after a 30‐min washout), and Regimen C (mechanical control: ETb + distilled water). Atomic force microscopy (AFM) quantified R a values at baseline and at 30 days. Data were evaluated using three‐way mixed ANOVA, one‐way ANOVA, and post hoc Bonferroni corrections ( p < 0.05).
Results
Three‐way mixed ANOVA revealed a significant interaction among time, surface type, and regimen ( F (2, 18) = 30.58, p < 0.001). Post hoc tests showed that Regimens A and B significantly increased R a values in Group 1 (A: p = 0.0001; B: p = 0.001) and in Group 2 (A: p = 0.005; B: p = 0.0008). Conversely, Regimen C produced no significant alterations ( p > 0.05). Baseline one‐way ANOVA confirmed that Group 2 possessed significantly higher R a values than Group 1 ( p < 0.001).
Conclusion
Exposure to therapeutic oral hygiene protocols (Regimens A and B) significantly elevated Ti6Al4V roughness, while isolated bristle friction (Regimen C) had a negligible impact. Pre‐textured sandblasted surfaces exhibited greater vulnerability to structural wear than polished surfaces, highlighting the need for surface‐specific, individualized implant hygiene protocols.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Periodontology, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, India.
ORCID-Profile: Vaishnavi Pandey, Rupali Agnihotri
Zitieren
APA
Pandey, V., & Agnihotri, R. (2026). Do Oral Hygiene Methods Alter Titanium Implant Surfaces? An In Vitro Surface Roughness Analysis. International Journal of Dental Hygiene. https://doi.org/10.1111/idh.70186
Vancouver
Pandey V, Agnihotri R. Do Oral Hygiene Methods Alter Titanium Implant Surfaces? An In Vitro Surface Roughness Analysis. International Journal of Dental Hygiene. 2026. doi:10.1111/idh.70186
BibTeX
@article{Pandey2026,
author = {Pandey, Vaishnavi and Agnihotri, Rupali},
title = {Do Oral Hygiene Methods Alter Titanium Implant Surfaces? An In Vitro Surface Roughness Analysis},
journal = {International Journal of Dental Hygiene},
year = {2026},
doi = {10.1111/idh.70186}
}