EUVIMEDEUVIMED entdecken
Crossref

In-Vitro Marginal Fit of 3D-Printed vs Milled Provisional Crowns

Reem Mohsen AlMutairi

Journal of Pioneering Medical Sciences · 05.09.2025 · 14 (S02) · 176-180

DOI: 10.47310/jpms202514s0227 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Pioneering Medical Sciences, online erschienen am 05.09.2025. Verfasst von Reem Mohsen AlMutairi. Die Arbeit wurde bisher 3-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Context

Provisional crowns are essential intermediate restorations in fixed prosthodontics, and marginal fit is a key determinant of periodontal health, pulpal protection, and long-term clinical success. Present CAD/CAM technologies allow for production by subtractive milling or additive manufacturing, each with inherent technical properties potentially influencing marginal fit. Comparative in-vitro evidence under controlled conditions, however is still limited in this regard, and controlled assessments have to be applied to inform fabrication method choice.

Methods

The laboratory-based experimental setup was used to compare the marginal fit of provisional crowns produced through digital CAD design followed by fabrication through 3D printing (n = 10) or milling (n = 10). Both the groups used a standardized tooth preparation and master die. All the crowns were produced from PMMA-based materials following the manufacturer's suggested parameters. Marginal gap was measured at four standardized positions on each crown—mid-buccal, mid-lingual, mid-mesial, and mid-distal—using a 50× magnification stereomicroscope. The data were 40 measurements per group. The data were tested for normality and compared using independent samples t-tests with the significance level at p < 0.05. Intra- and inter-examiner reliability were also tested using intraclass correlation coefficients (ICCs). Outcomes: The group mean marginal gap in the 3D-printed cohort was 95.8 ± 8.5 μm, whereas the milled cohort had a mean of 73.1 ± 7.0 μm. The mean difference recorded between the cohorts was 22.7 μm, the difference that was statistically significant (t = 8.56, p < 0.001), with a substantial effect size (Cohen's d = 1.92). Site-specific tests also revealed that at all four marginal sites measured, the milled crowns had consistently smaller gaps, with p-values of less than 0.001 for all the tests. Intraclass correlation coefficients (ICCs) for intra- and inter-examiner measurements were greater than 0.97, reflecting excellent measurement reliability. Qualitative synthesis revealed that the crowns 3D-printed showed slightly greater variability at the marginal areas, which was generally because of small differences in junction surface smoothness, whereas the milled crowns showed more uniform adaptation.

Conclusion

Within the constraints of this in vitro investigation, milled provisional crowns exhibited significantly reduced marginal discrepancies with improved fit uniformity over their 3D-printed counterparts. Both techniques yielded results within clinical acceptable margins, demonstrating, however, that although milling may be more suited, 3D printing is also a useful alternative if manufacturing efficiency or material usage is the priority.

Zitieren

APA

AlMutairi, R. M. (2025). In-Vitro Marginal Fit of 3D-Printed vs Milled Provisional Crowns. Journal of Pioneering Medical Sciences, 14(S02), 176-180. https://doi.org/10.47310/jpms202514s0227

Vancouver

AlMutairi RM. In-Vitro Marginal Fit of 3D-Printed vs Milled Provisional Crowns. Journal of Pioneering Medical Sciences. 2025;14(S02):176-180. doi:10.47310/jpms202514s0227

BibTeX
@article{AlMutairi2025,
  author = {AlMutairi, Reem Mohsen},
  title = {In-Vitro Marginal Fit of 3D-Printed vs Milled Provisional Crowns},
  journal = {Journal of Pioneering Medical Sciences},
  year = {2025},
  volume = {14},
  number = {S02},
  pages = {176--180},
  doi = {10.47310/jpms202514s0227}
}
Kostenlos starten →