EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The fracture resistance of 3D-printed versus milled provisional crowns: An in vitro study

Ahmed Othman iD, Maximillian Sandmair, Vasilios Alevizakos iD, Constantin von See

PLOS ONE · 01.09.2023 · 18 (9) · e0285760

DOI: 10.1371/journal.pone.0285760 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 01.09.2023. Verfasst von Ahmed Othman und 3 weiteren Autor:innen. Beteiligte Einrichtung: Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private Univers…. Hauptthemen laut MEDLINE: Molar, Fractures, Bone. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

CAD/CAM has considerably transformed the clinical practice of dentistry. In particular, advanced dental materials produced via digital technologies offer unquestionable benefits, such as ideal mechanical stability, outstanding aesthetics and reliable high precision. Additive manufacturing (AM) technology has promoted new innovations, especially in the field of biomedicine.

Aims

The aim of this study is to analyze the fracture resistance of implant-supported 3D-printed temporary crowns relative to milled crowns by compression testing.

Methods

The study sample included 32 specimens of temporary crowns, which were divided into 16 specimens per group. Each group consisted of eight maxillary central incisor crowns (tooth 11) and eight maxillary molar crowns (tooth 16). The first group (16 specimens) was 3D printed by a mask printer (Varseo, BEGO, Bremen, Germany) with a temporary material (VarseoSmile Temp A3, BEGO, Bremen, Germany). The second group was milled with a millable temporary material (VitaCAD Temp mono-color, Vita, Bad Säckingen, Germany). The two groups were compression tested until failure to estimate their fracture resistance. The loading forces and travel distance until failure were measured. The statistical analysis was performed using SPSS Version 24.0. We performed multiple t tests and considered a significance level of p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MolarFractures, BoneHumansIncisorResearch DesignCuspidPrinting, Three-Dimensional

Autor:innen und Institutionen

  • Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, Krems, Austria.

ORCID-Profile: Ahmed Othman, Vasilios Alevizakos

Zitieren

APA

Othman, A., Sandmair, M., Alevizakos, V., & von See, C. (2023). The fracture resistance of 3D-printed versus milled provisional crowns: An in vitro study. PLOS ONE, 18(9), e0285760. https://doi.org/10.1371/journal.pone.0285760

Vancouver

Othman A, Sandmair M, Alevizakos V, von See C. The fracture resistance of 3D-printed versus milled provisional crowns: An in vitro study. PLOS ONE. 2023;18(9):e0285760. doi:10.1371/journal.pone.0285760

BibTeX
@article{Othman2023,
  author = {Othman, Ahmed and Sandmair, Maximillian and Alevizakos, Vasilios and von See, Constantin},
  title = {The fracture resistance of 3D-printed versus milled provisional crowns: An in vitro study},
  journal = {PLOS ONE},
  year = {2023},
  volume = {18},
  number = {9},
  pages = {e0285760},
  doi = {10.1371/journal.pone.0285760}
}
Kostenlos starten →