Quantitative analysis of peri-implant collagen fiber orientation around external hexagon and Morse taper implant connections: A dog model study
Journal of Clinical and Experimental Dentistry · 2026 · e961-e967
DOI: 10.4317/jced.64278 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Clinical and Experimental Dentistry, 2026. Verfasst von Daniel Sartorelli Marques de Castro und 7 weiteren Autor:innen. Beteiligte Einrichtung: Professor of Prosthodontics, Department of Dentistry, University Christus, Fortaleza, Ceará, Brazil. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Peri-implant soft tissue stability depends on the implant-abutment interface and collagen fiber organization. Unlike natural teeth, peri-implant fibers exhibit a less favorable orientation, potentially weakening the biological seal. Implant connection design may influence this collagen arrangement and tissue integrity. Materials and Methods: Eighteen immediately loaded implants (n = 9 per group) were placed in nine mongrel dogs. Group I received external hexagon implants, while Group II received Morse taper implants. After a 4-month healing period, animals were euthanized and specimens were processed for histological evaluation. Collagen fiber orientation was analyzed using polarized light microscopy and quantified with ImageJ software. Statistical analysis was performed using the Mann-Whitney U test ( = 0.05).
Results
Group I exhibited predominantly parallel and parallel-oblique collagen fibers, with mean orientations of 19.88° (buccal) and 21.92° (lingual). In contrast, Group II showed mainly oblique and oblique-perpendicular fibers, with mean orientations of 70.20° (buccal) and 54.73° (lingual). No significant differences were observed between buccal and lingual aspects within each group (p > 0.05). However, a significant difference was observed between implant connection types, with Group II presenting a significantly higher proportion of oblique and oblique-perpendicular fibers compared with Group I (p = 0.004; r = 0.71).
Conclusions
Morse taper implants were associated with a more perpendicular collagen fiber orientation, which may enhance the biological seal of peri-implant soft tissues.
Autor:innen und Institutionen
- Professor of Prosthodontics, Department of Dentistry, University Christus, Fortaleza, Ceará, Brazil.
- PhD, Department of Biomaterials, Dental Materials and Prosthodontics, Sao Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos, São Paulo, Brazil.
- Professor of Prosthodontics and Occlusion, Department of Dentistry, Universidade Federal do Ceará UFC, Fortaleza, Ceará, Brazil.
- Private Surgery Clinician, Bauru, University of São Paulo, Bauru, SP, Brazil.
- Professor, Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School (FOP UNICAMP), Piracicaba, São Paulo, Brazil.
- DDS, MSc, PhD. Associate Professor, Department of Restorative Sciences and Public Health Dentistry, Nova Southeastern University College of Dental Medicine, Fort Lauderdale, Florida, USA.
Zitieren
APA
Marques de Castro, D. S., Melo de Matos, J. D., Mello Lima, J. F., Rehder de Araujo, M. A., Coelho Sinhoreti, M. A., Queiroz, D. A., Piattelli, A., & Dos Reis Pereira de Araújo, C. (2026). Quantitative analysis of peri-implant collagen fiber orientation around external hexagon and Morse taper implant connections: A dog model study. Journal of Clinical and Experimental Dentistry, e961-e967. https://doi.org/10.4317/jced.64278
Vancouver
Marques de Castro DS, Melo de Matos JD, Mello Lima JF, Rehder de Araujo MA, Coelho Sinhoreti MA, Queiroz DA, et al. Quantitative analysis of peri-implant collagen fiber orientation around external hexagon and Morse taper implant connections: A dog model study. Journal of Clinical and Experimental Dentistry. 2026:e961-e967. doi:10.4317/jced.64278
BibTeX
@article{MarquesdeCastro2026,
author = {Marques de Castro, Daniel Sartorelli and Melo de Matos, Jefferson David and Mello Lima, Jozely Francisca and Rehder de Araujo, Maria Angelica and Coelho Sinhoreti, Mário Alexandre and Queiroz, Daher Antonio and Piattelli, Adriano and Dos Reis Pereira de Araújo, Carlos},
title = {Quantitative analysis of peri-implant collagen fiber orientation around external hexagon and Morse taper implant connections: A dog model study},
journal = {Journal of Clinical and Experimental Dentistry},
year = {2026},
pages = {e961--e967},
doi = {10.4317/jced.64278}
}
EUVIMED