EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Microtomographic Characterization of Morse-Tapered Implant Systems as Material–Biological Interfaces: Implications for Peri-Implant Soft Tissue Stability

Michele Furlani iD, Carmen Mortellaro, Alessandra Giuliani iD

Materials · 03.08.2026 · 19 (15) · 3272

DOI: 10.3390/ma19153272 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Materials, online erschienen am 03.08.2026. Verfasst von Michele Furlani und 2 weiteren Autor:innen. Beteiligte Einrichtung: Dipartimento di Scienze della Vita, della Salute e delle Professioni Sanitarie, Universita degli Studi "Link Campus University", 00165 Rome, Italy. Die Arbeit nennt 83 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Advanced dental implant systems are clinically successful when their material properties, surface topography, abutment geometry and implant–abutment connection design support both mechanical stability and biological integration. In Morse-tapered implant–abutment systems and conometric prosthetic retention systems, the precision of conical interfaces has traditionally been discussed mainly in biomechanical terms; however, their clinical performance also depends on the formation and maintenance of a stable peri-implant soft tissue seal. This review examines micro-computed tomography (µCT), with emphasis on synchrotron radiation-based phase-contrast micro-computed tomography (SR-PhC-µCT), as an advanced characterization strategy for evaluating how implant and abutment design influence the three-dimensional architecture of peri-implant connective tissues. The review summarizes the biological organization of the peri-implant mucosa, the technical basis of absorption- and phase-contrast microtomography, sample preparation protocols, segmentation workflows, artificial intelligence-assisted image analysis and quantitative morphometric descriptors of collagen organization. Particular attention is given to human retrieval and biopsy studies of Morse-tapered/conometric systems, where three-dimensional imaging has revealed interwoven circumferential and longitudinal collagen bundles around the transmucosal implant component. These microarchitectural features have been directly visualized by SR-PhC-µCT and histology and may represent a biomechanically plausible basis for mucosal sealing and force distribution. However, their direct relationship with marginal bone preservation and long-term clinical outcomes remains to be demonstrated in longitudinal studies. Within the scope of advanced dental materials, the novelty of this review lies in framing SR-PhC-µCT, correlative histology and AI-assisted segmentation as enabling tools within a materials-design framework for implant–abutment optimization. In this framework, peri-implant collagen architecture is interpreted as an exploratory structural readout of the interaction among connection design, abutment geometry, surface topography and biological response. This approach does not yet establish validated clinical biomarkers, but it may generate testable hypotheses for future studies aimed at improving peri-implant soft tissue stability and implant–abutment system design.

Schlagwörter

Stichwörter der Autor:innen

Morse-tapered connectionabutment geometryabutment–prosthetic interfaceconometric retentionimplant–abutment interfacemicro-computed tomographyperi-implant soft tissuesurface topography

Autor:innen und Institutionen

  • Dipartimento di Scienze della Vita, della Salute e delle Professioni Sanitarie, Universita degli Studi "Link Campus University", 00165 Rome, Italy.
  • Departmental Faculty of Medicine, UniCamillus-Saint Camillus International University of Health Sciences, 00131 Rome, Italy.
  • Dipartimento di Scienze Cliniche Specialistiche e Odontostomatologiche, Universita Politecnica delle Marche, 60131 Ancona, Italy.

ORCID-Profile: Michele Furlani, Alessandra Giuliani

Zitieren

APA

Furlani, M., Mortellaro, C., & Giuliani, A. (2026). Microtomographic Characterization of Morse-Tapered Implant Systems as Material–Biological Interfaces: Implications for Peri-Implant Soft Tissue Stability. Materials, 19(15), 3272. https://doi.org/10.3390/ma19153272

Vancouver

Furlani M, Mortellaro C, Giuliani A. Microtomographic Characterization of Morse-Tapered Implant Systems as Material–Biological Interfaces: Implications for Peri-Implant Soft Tissue Stability. Materials. 2026;19(15):3272. doi:10.3390/ma19153272

BibTeX
@article{Furlani2026,
  author = {Furlani, Michele and Mortellaro, Carmen and Giuliani, Alessandra},
  title = {Microtomographic Characterization of Morse-Tapered Implant Systems as Material–Biological Interfaces: Implications for Peri-Implant Soft Tissue Stability},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {15},
  pages = {3272},
  doi = {10.3390/ma19153272}
}
Kostenlos starten →