EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of Microstrain in the Regions Surrounding Morse Taper and External Hexagon Implants

André Luiz de Melo Moreno iD, Marcio Campaner, Clóvis Lamartine de Moraes Melo Neto iD, Nathaly Vilene de Araújo Moreno, Daniela Micheline Dos Santos, Marcelo Coelho Goiato iD

European Journal of Dentistry · 01.02.2025 · 19 (01) · 180-186

DOI: 10.1055/s-0044-1787696 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Dentistry, erschienen am 01.02.2025. Verfasst von André Luiz de Melo Moreno und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), School of Dentistry, Araçatuba, São Paulo, Brazil. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The aim of this study was to compare the Morse taper (MT) + titanium base (Ti-Base) abutment with the external hexagon (EH) + Ti-Base abutment by using the strain gauge method in the mesial, distal, and apical–buccal areas around these types of implants. Materials and Methods This study investigated two groups, MT and EH, each comprising five polyurethane samples with a dental implant (3.75 × 11.5 mm) in the area of artificial tooth 15. The strain gauges were glued to the mesial, distal, and apical–buccal polyurethane areas of all samples in relation to the implant. Ti-Base nonangled abutments were installed on the implants in each group. Ten identical zirconia crowns were constructed by scanning and milling and were subsequently cemented onto the Ti-base abutments with calcium hydroxide cement. Then, an axial load of 100 N was applied to the occlusal region of the zirconia crowns, and strain gauge measurements were taken. Statistical Analysis Strain gauge data were assessed by a two-way analysis of variance (ANOVA) with “implant connection” and “strain gauge position” factors, followed by the Bonferroni test (p < 0.05).

Results

The MT group showed significantly lower microstrain values in the mesial and apical strain gauges compared to the EH group.

Conclusion

The MT group exhibited less microstrain in the mesial and apical areas of the polyurethane samples near the implant. Consequently, the MT connection was considered more biomechanically advantageous.

Autor:innen und Institutionen

  • Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), School of Dentistry, Araçatuba, São Paulo, Brazil.
  • Courses in Dentistry (IEEP - Instituto de Excelência em Ensino e Pesquisa), Manaus, Amazonas, Brazil.

ORCID-Profile: André Luiz de Melo Moreno, Clóvis Lamartine de Moraes Melo Neto, Marcelo Coelho Goiato

Zitieren

APA

Moreno, A. L. M., Campaner, M., de Moraes Melo Neto, C. L., Moreno, N. V. A., Dos Santos, D. M., & Goiato, M. C. (2025). Evaluation of Microstrain in the Regions Surrounding Morse Taper and External Hexagon Implants. European Journal of Dentistry, 19(01), 180-186. https://doi.org/10.1055/s-0044-1787696

Vancouver

Moreno ALM, Campaner M, de Moraes Melo Neto CL, Moreno NVA, Dos Santos DM, Goiato MC. Evaluation of Microstrain in the Regions Surrounding Morse Taper and External Hexagon Implants. European Journal of Dentistry. 2025;19(01):180-186. doi:10.1055/s-0044-1787696

BibTeX
@article{Moreno2025,
  author = {Moreno, André Luiz de Melo and Campaner, Marcio and de Moraes Melo Neto, Clóvis Lamartine and Moreno, Nathaly Vilene de Araújo and Dos Santos, Daniela Micheline and Goiato, Marcelo Coelho},
  title = {Evaluation of Microstrain in the Regions Surrounding Morse Taper and External Hexagon Implants},
  journal = {European Journal of Dentistry},
  year = {2025},
  volume = {19},
  number = {01},
  pages = {180--186},
  doi = {10.1055/s-0044-1787696}
}
Kostenlos starten →