EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Development and preliminary evaluation of a low-cost polylactic acid three-dimensional-printed lumbar vertebral model for spine surgical training

Alexander J. Potts, Kyle Ortiz Rodriguez, Andrew J. Witten, Chiara A. Flores, Ben Loflin, Stephen Schlecht, Gordon Mao

Journal of Craniovertebral Junction and Spine · 2026-11 · 17 (6) · 649-654

DOI: 10.4103/jcvjs.jcvjs_159_26 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Craniovertebral Junction and Spine, online erschienen am 20.11.2026. Verfasst von Alexander J. Potts und 6 weiteren Autor:innen. Die Arbeit nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The study aimed to develop a low-cost, three-dimensional-printed lumbar vertebral model that enhances the tactile transition between cortical and cancellous bone using a digitally defined cortical shell–infill gap and to perform a preliminary evaluation of perceived realism across common spine surgical tasks.

Methods

An L4 model was printed in polylactic acid (PLA) with a single cortical shell separated from the trabecular region by a 0.4-mm shell–infill gap over 30% gyroid infill. Iterative prototyping and a pilot round (2 raters) informed final parameters. Ten nonauthor evaluators (three attendings, five senior residents, and two junior residents) performed high-speed drilling, pedicle probe cannulation, tapping/screw insertion, and laminar rongeuring. Realism was rated on a six-domain, 5-point instrument (visual realism, drilling resistance, cortical–cancellous transition, screw purchase, rongeur response, and auditory/vibratory cues). Scores were summarized as mean ± standard deviation (SD); internal consistency was assessed using Cronbach’s alpha. Free-text comments captured recurrent issues.

Results

Across all raters, the model demonstrated moderate-to-high realism. The mean (±SD) scores were visual realism – 3.3 ± 0.8, drilling resistance – 3.5 ± 0.7, cortical–cancellous transition – 3.8 ± 0.9 (highest), screw insertion/purchase – 3.5 ± 1.0, rongeur response – 3.1 ± 0.7 (lowest), and auditory/vibratory cues – 3.6 ± 1.3. Questionnaire reliability was acceptable (Cronbach’s alpha = 0.79). As an exploratory, nontested observation, junior residents tended to provide higher total ratings than attendings (mean total: 23 vs. 20 of 30). Pilot testing supported the 0.4-mm gap and increased infill to accentuate the cortical “pop.” Recurrent comments noted occasional PLA softening during sustained high-speed drilling.

Conclusions

A PLA model with a thin shell–infill gap provides credible, low-cost haptics for core spine tasks, particularly the cortical–cancellous transition. The tunable architecture (shell, gap, and infill) supports task- or anatomy-specific optimization and lays groundwork for multisegment and multimaterial expansions. Comparative evaluation against cadaveric and commercial models using a validated instrument is a needed next step.

Zitieren

APA

Potts, A. J., Rodriguez, K. O., Witten, A. J., Flores, C. A., Loflin, B., Schlecht, S., & Mao, G. (2026). Development and preliminary evaluation of a low-cost polylactic acid three-dimensional-printed lumbar vertebral model for spine surgical training. Journal of Craniovertebral Junction and Spine, 17(6), 649-654. https://doi.org/10.4103/jcvjs.jcvjs_159_26

Vancouver

Potts AJ, Rodriguez KO, Witten AJ, Flores CA, Loflin B, Schlecht S, et al. Development and preliminary evaluation of a low-cost polylactic acid three-dimensional-printed lumbar vertebral model for spine surgical training. Journal of Craniovertebral Junction and Spine. 2026;17(6):649-654. doi:10.4103/jcvjs.jcvjs_159_26

BibTeX
@article{Potts2026,
  author = {Potts, Alexander J. and Rodriguez, Kyle Ortiz and Witten, Andrew J. and Flores, Chiara A. and Loflin, Ben and Schlecht, Stephen and Mao, Gordon},
  title = {Development and preliminary evaluation of a low-cost polylactic acid three-dimensional-printed lumbar vertebral model for spine surgical training},
  journal = {Journal of Craniovertebral Junction and Spine},
  year = {2026},
  volume = {17},
  number = {6},
  pages = {649--654},
  doi = {10.4103/jcvjs.jcvjs_159_26}
}
Kostenlos starten →