Development and preliminary evaluation of a low-cost polylactic acid three-dimensional-printed lumbar vertebral model for spine surgical training
Journal of Craniovertebral Junction and Spine · 2026-11 · 17 (6) · 649-654
DOI: 10.4103/jcvjs.jcvjs_159_26 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Craniovertebral Junction and Spine, online erschienen am 20.11.2026. Verfasst von Alexander J. Potts und 6 weiteren Autor:innen. Die Arbeit nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objective
The study aimed to develop a low-cost, three-dimensional-printed lumbar vertebral model that enhances the tactile transition between cortical and cancellous bone using a digitally defined cortical shell–infill gap and to perform a preliminary evaluation of perceived realism across common spine surgical tasks.
Methods
An L4 model was printed in polylactic acid (PLA) with a single cortical shell separated from the trabecular region by a 0.4-mm shell–infill gap over 30% gyroid infill. Iterative prototyping and a pilot round (2 raters) informed final parameters. Ten nonauthor evaluators (three attendings, five senior residents, and two junior residents) performed high-speed drilling, pedicle probe cannulation, tapping/screw insertion, and laminar rongeuring. Realism was rated on a six-domain, 5-point instrument (visual realism, drilling resistance, cortical–cancellous transition, screw purchase, rongeur response, and auditory/vibratory cues). Scores were summarized as mean ± standard deviation (SD); internal consistency was assessed using Cronbach’s alpha. Free-text comments captured recurrent issues.
Results
Across all raters, the model demonstrated moderate-to-high realism. The mean (±SD) scores were visual realism – 3.3 ± 0.8, drilling resistance – 3.5 ± 0.7, cortical–cancellous transition – 3.8 ± 0.9 (highest), screw insertion/purchase – 3.5 ± 1.0, rongeur response – 3.1 ± 0.7 (lowest), and auditory/vibratory cues – 3.6 ± 1.3. Questionnaire reliability was acceptable (Cronbach’s alpha = 0.79). As an exploratory, nontested observation, junior residents tended to provide higher total ratings than attendings (mean total: 23 vs. 20 of 30). Pilot testing supported the 0.4-mm gap and increased infill to accentuate the cortical “pop.” Recurrent comments noted occasional PLA softening during sustained high-speed drilling.
Conclusions
A PLA model with a thin shell–infill gap provides credible, low-cost haptics for core spine tasks, particularly the cortical–cancellous transition. The tunable architecture (shell, gap, and infill) supports task- or anatomy-specific optimization and lays groundwork for multisegment and multimaterial expansions. Comparative evaluation against cadaveric and commercial models using a validated instrument is a needed next step.
Zitieren
APA
Potts, A. J., Rodriguez, K. O., Witten, A. J., Flores, C. A., Loflin, B., Schlecht, S., & Mao, G. (2026). Development and preliminary evaluation of a low-cost polylactic acid three-dimensional-printed lumbar vertebral model for spine surgical training. Journal of Craniovertebral Junction and Spine, 17(6), 649-654. https://doi.org/10.4103/jcvjs.jcvjs_159_26
Vancouver
Potts AJ, Rodriguez KO, Witten AJ, Flores CA, Loflin B, Schlecht S, et al. Development and preliminary evaluation of a low-cost polylactic acid three-dimensional-printed lumbar vertebral model for spine surgical training. Journal of Craniovertebral Junction and Spine. 2026;17(6):649-654. doi:10.4103/jcvjs.jcvjs_159_26
BibTeX
@article{Potts2026,
author = {Potts, Alexander J. and Rodriguez, Kyle Ortiz and Witten, Andrew J. and Flores, Chiara A. and Loflin, Ben and Schlecht, Stephen and Mao, Gordon},
title = {Development and preliminary evaluation of a low-cost polylactic acid three-dimensional-printed lumbar vertebral model for spine surgical training},
journal = {Journal of Craniovertebral Junction and Spine},
year = {2026},
volume = {17},
number = {6},
pages = {649--654},
doi = {10.4103/jcvjs.jcvjs_159_26}
}
EUVIMED