EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Evaluating the efficacy of a cost-effective, fully three-dimensional-printed vertebra model for endoscopic spine surgery training for neurosurgical residents

Bilal Bahadır Akbulut, Mustafa Serdar Bölük, Hüseyin Biçeroğlu, Taşkın Yurtseven

Asian Spine Journal · 31.10.2024 · 18 (5) · 630-638

DOI: 10.31616/asj.2024.0288 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Asian Spine Journal, erschienen am 31.10.2024. Verfasst von Bilal Bahadır Akbulut und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Ege University Faculty of Medicine, Izmir, Turkey. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Study Design: A fused deposition modeling three-dimensional (3D)-printed model of the L4–5 vertebra for lumbar discectomy was designed. The model included separately printed dura mater, spinal cord, ligamentum flavum, intervertebral disc (from thermoplastic polyurethane), and bony structures (from polylactic acid), and the material cost approximately US$ 1 per model. A simple plumbing endoscope was used for visualization. Dura mater injury was assessed by painting two layers on the dura mater, which peeled off with trauma.

Purpose

Endoscopic spine surgery is a subject of high interest in neurosurgery given its minimally invasive nature; however, it has a steep learning curve. This study evaluated the effectiveness of a cost-efficient 3D-printed model when teaching this technique to neurosurgery residents.Overview of Literature: Only a few studies have investigated the efficacy of such a model.

Methods

Eight residents with >2 years of training participated. Residents performed the procedure bilaterally and twice at 1-week intervals.

Results

From the 32 surgeries, four were excluded because of facet removal (as it widened the surgical corridor), leaving 28 surgeries for analysis. Initial surgeries demonstrated a mean operation time of 21 minutes 18 seconds (standard deviation [SD], 2 minutes 32 seconds), which improved to a mean of 6 minutes 45 seconds (SD, 37 seconds) in the fourth surgery (F(3, 17)=19.18, p

Schlagwörter

Stichwörter der Autor:innen

3D printingEndoscopesMinimally invasive surgical proceduresResidencySimulation training

Autor:innen und Institutionen

  • Department of Neurosurgery, Ege University Faculty of Medicine, Izmir, Turkey.

Zitieren

APA

Akbulut, B. B., Bölük, M. S., Biçeroğlu, H., & Yurtseven, T. (2024). Evaluating the efficacy of a cost-effective, fully three-dimensional-printed vertebra model for endoscopic spine surgery training for neurosurgical residents. Asian Spine Journal, 18(5), 630-638. https://doi.org/10.31616/asj.2024.0288

Vancouver

Akbulut BB, Bölük MS, Biçeroğlu H, Yurtseven T. Evaluating the efficacy of a cost-effective, fully three-dimensional-printed vertebra model for endoscopic spine surgery training for neurosurgical residents. Asian Spine Journal. 2024;18(5):630-638. doi:10.31616/asj.2024.0288

BibTeX
@article{Akbulut2024,
  author = {Akbulut, Bilal Bahadır and Bölük, Mustafa Serdar and Biçeroğlu, Hüseyin and Yurtseven, Taşkın},
  title = {Evaluating the efficacy of a cost-effective, fully three-dimensional-printed vertebra model for endoscopic spine surgery training for neurosurgical residents},
  journal = {Asian Spine Journal},
  year = {2024},
  volume = {18},
  number = {5},
  pages = {630--638},
  doi = {10.31616/asj.2024.0288}
}
Kostenlos starten →