The Logarithmically Unified Normative Acuity Set: A psychometrically equalized optotype alphabet for visual acuity assessment – Derivation and clinical validation
Journal of Clinical Ophthalmology and Research · 2026-10 · 14 (4) · 386-392
DOI: 10.4103/jcor.jcor_319_26 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Ophthalmology and Research, online erschienen am 18.11.2026. Verfasst von Juan C. L. Costa und 5 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
The Sloan alphabet differs appreciably between letters in discriminability, an asymmetry uniform per-line sizing leaves uncorrected. We aimed to derive and validate the Logarithmically Unified Normative Acuity (L.U.N.A.) Set, a ten-letter alphabet rescaled via Bayesian psychophysics, Monte Carlo optimization, and structural-similarity calibration. Materials and Methods: In a single-center, prospective, three-phase study, Phase I ( n = 41) psychometrically characterized 26 Latin letters; 50,000 Monte Carlo simulations selected ten letters (U, V, Z, A, X, N, O, E, P, R). Phase II used Structural Similarity Index (SSIM) analysis at ~68 pixels per inch (ppi) to calibrate size-correction factors. Phase III ( n = 110) provided clinical validation, assessing misidentification rate, partial-line frequency, Bland–Altman agreement, and the intraclass correlation coefficient (ICC).
Results
Bland–Altman analysis confirmed metric compatibility with the Early Treatment Diabetic Retinopathy Study (ETDRS) logarithm of the minimum angle of resolution (logMAR) scale (bias +0.35 letters; 95% confidence interval [CI]: 0.29–0.42; limits of agreement −1.5 to +2.2 letters). Per-letter confusion fell 57% ( P < 0.001), and partial-line frequency fell from 24.7% to 17.3% ( P = 0.001). Test–retest ICC rose from 0.729 (95% CI: 0.637–0.804) to 0.889 (95% CI: 0.851–0.919), nonoverlapping intervals.
Conclusion
Bayesian threshold estimation, Monte Carlo letter selection, and size-correction factors together yielded a 57% reduction in per-letter confusion, a steeper psychometric transition, and higher test–retest reliability than Classic Sloan, without sacrificing ETDRS logMAR compatibility. Requiring no change in protocol or hardware, the L.U.N.A. Set is a font-based, ready-to-use refinement of digital visual acuity assessment, valuable for longitudinal follow-up.
Zitieren
APA
Costa, J. C. L., Nascimento, R. B. M., Martins, E. M. A., Ricarte, A. J., Mangueira, P. K. C. A., & Bezerra, H. D. L. (2026). The Logarithmically Unified Normative Acuity Set: A psychometrically equalized optotype alphabet for visual acuity assessment – Derivation and clinical validation. Journal of Clinical Ophthalmology and Research, 14(4), 386-392. https://doi.org/10.4103/jcor.jcor_319_26
Vancouver
Costa JCL, Nascimento RBM, Martins EMA, Ricarte AJ, Mangueira PKCA, Bezerra HDL. The Logarithmically Unified Normative Acuity Set: A psychometrically equalized optotype alphabet for visual acuity assessment – Derivation and clinical validation. Journal of Clinical Ophthalmology and Research. 2026;14(4):386-392. doi:10.4103/jcor.jcor_319_26
BibTeX
@article{Costa2026,
author = {Costa, Juan C. L. and Nascimento, Raquel B. M. and Martins, Edine M. A. and Ricarte, Arsênio J. and Mangueira, Pedro K. C. A. and Bezerra, Haroldo de L.},
title = {The Logarithmically Unified Normative Acuity Set: A psychometrically equalized optotype alphabet for visual acuity assessment – Derivation and clinical validation},
journal = {Journal of Clinical Ophthalmology and Research},
year = {2026},
volume = {14},
number = {4},
pages = {386--392},
doi = {10.4103/jcor.jcor_319_26}
}
EUVIMED