A Comparative Validation Study of Near Visual Acuity Assessment Using Different Handheld Acuity Charts
Ophthalmology Science · 2025-09 · 5 (5) · 100790
DOI: 10.1016/j.xops.2025.100790 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ophthalmology Science, 2025-09. Verfasst von David Ziyou Chen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, National University Hospital, Singapore. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National University Health System.
Abstract (Originalsprache)
Objective
To develop a conversion table and compare the cross-validity of 3 types of widely utilized near vision charts: the ETDRS near chart, the N-notation chart, and the Rosenbaum chart.
Design
A prospective, cross-sectional, comparative validation study.
Participants
Aged ≥40 years.
Methods
A conversion table for the 3 types of near charts was created using objective character sizing based on vertical height captured using a surgical microscope with a 10× magnification. Eligible presbyopic patients had their near vision tested sequentially with 3 near charts in a randomized order. Main Outcome Measures: Pearson correlation coefficient (r) for the relationship among the near visual acuity charts. The consistency between the different charts was evaluated by Bland-Altman diagrams.
Results
A total of 204 participants (129 women, 63.2%) were recruited for the study (mean age, 58.9 ± 7.1 years). For correlation, r ranged from 0.596 to 0.836 (all P < 0.001). The Rosenbaum chart had the smallest range of difference against the ETDRS chart (standard deviation [SD] = 0.12), followed by the N-notation chart (SD = 0.15). Most of the converted logarithm of the minimum angle of resolution (logMAR) values from the N-notation and Rosenbaum charts were between 0.0 and 0.1 higher than the ETDRS logMAR equivalent (range: 0.07-0.11), with a tendency for both the N-notation and Rosenbaum charts to overestimate logMAR at more positive values.
Conclusions
We have developed a conversion table for 3 types of commonly used near vision charts. When compared with the ETDRS near chart, the Rosenbaum chart had a smaller range of difference than the N-notation chart. Both the Rosenbaum and N-notation charts tended to underestimate near vision at worse vision. Financial Disclosures: The author(s) have no proprietary or commercial interest in any materials discussed in this article.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, National University Hospital, Singapore.
- Centre for Innovation and Precision Eye Health, Yong Loo Lin School of Medicine, National University of Singapore, Singapore.
- Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore.
- Biostatistics Unit, Yong Loo Lin School of Medicine, Singapore.
- Singapore National Eye Centre, Singapore.
- Singapore Eye Research Institute, Singapore.
Förderung
- National University Health System
Zitieren
APA
Chen, D. Z., Tham, Y. C., Shen, L., & Chee, S. P. (2025). A Comparative Validation Study of Near Visual Acuity Assessment Using Different Handheld Acuity Charts. Ophthalmology Science, 5(5), 100790. https://doi.org/10.1016/j.xops.2025.100790
Vancouver
Chen DZ, Tham YC, Shen L, Chee SP. A Comparative Validation Study of Near Visual Acuity Assessment Using Different Handheld Acuity Charts. Ophthalmology Science. 2025;5(5):100790. doi:10.1016/j.xops.2025.100790
BibTeX
@article{Chen2025,
author = {Chen, David Ziyou and Tham, Yih-Chung and Shen, Liang and Chee, Soon-Phaik},
title = {A Comparative Validation Study of Near Visual Acuity Assessment Using Different Handheld Acuity Charts},
journal = {Ophthalmology Science},
year = {2025},
volume = {5},
number = {5},
pages = {100790},
doi = {10.1016/j.xops.2025.100790}
}
EUVIMED