Clinical validation of a novel smartphone application for measuring best corrected visual acuity
Journal of Optometry · 2023-07 · 16 (3) · 206-213
DOI: 10.1016/j.optom.2023.01.001 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Optometry, 2023-07. Verfasst von Mari Ogino und 8 weiteren Autor:innen. Beteiligte Einrichtung: Creighton University School of Medicine, Omaha, NE, United States. Hauptthemen laut MEDLINE: Mobile Applications. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
PURPOSE: Personal mobile devices such as smartphones are proving their usefulness in ever more applications in tele-eyecare. An inconvenience and potential source of error in these past approaches stemmed from the requirement for the subjects to situate their devices at a distance. The present study aims to clinically validate best corrected visual acuity (BCVA) measures carried out by a novel smartphone application "vision.app" (VisionApp Solutions S.L.) using comparative statistics against clinical measurements. MATERIALS AND METHODS: BCVA was measured in both eyes of 40 subjects using vision.app which displayed a black Landolt-C optotype with crowding on a white background, and utilized a 4 forced-choice procedure for the subjects to find (by means of swiping in either of four directions) the smallest optotype size they could resolve. Results were compared to BCVA measurements taken using a standard Snellen chart placed at 20 feet (6 m). RESULTS: The t-test revealed no significant differences between the app- and clinically-measured VA (p = 0.478 (OD) and 0.608 (OS)), with a mean difference between clinical and app measurements of less than one line of the eye chart (-0.009 logMAR (OD) and -0.005 logMAR (OS)). A limit of agreement for a 95% confidence interval of ± 0.08 logMAR for OD and OS was found. CONCLUSIONS: The results show the potential use of a smartphone to measure BCVA at a handheld distance. The newly validated study results can hold major future advancements in tele-eyecare and provide eye care professionals with a reliable and accessible method to measure BCVA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Creighton University School of Medicine, Omaha, NE, United States.
- Grupo de Ciencias de La Visión (CiViUM), Facultad de Óptica y Optometría, Universidad de Murcia, Murcia, Spain. Electronic address: rmsalmeroncampillo@gmail.com.
- University of California Riverside School of Medicine, Riverside, CA, United States.
- University of California Irvine School of Medicine, Irvine, CA, United States.
- Grupo de Ciencias de La Visión (CiViUM), Facultad de Óptica y Optometría, Universidad de Murcia, Murcia, Spain; Clínica Universitaria de Visión Integral (CUVI), Universidad de Murcia, Murcia, Spain.
- Grupo de Ciencias de La Visión (CiViUM), Facultad de Óptica y Optometría, Universidad de Murcia, Murcia, Spain; Clinical Optics Research Lab (CORL), Indiana University, Bloomington, IN, United States.
Zitieren
APA
Ogino, M., Salmerón-Campillo, R. M., Hunter, S., Hussey, V., Suh, D., Gore, R., López-Gil, N., Jaskulski, M., & Piña-Miguelsanz, D. (2023). Clinical validation of a novel smartphone application for measuring best corrected visual acuity. Journal of Optometry, 16(3), 206-213. https://doi.org/10.1016/j.optom.2023.01.001
Vancouver
Ogino M, Salmerón-Campillo RM, Hunter S, Hussey V, Suh D, Gore R, et al. Clinical validation of a novel smartphone application for measuring best corrected visual acuity. Journal of Optometry. 2023;16(3):206-213. doi:10.1016/j.optom.2023.01.001
BibTeX
@article{Ogino2023,
author = {Ogino, Mari and Salmerón-Campillo, Rosa María and Hunter, Stephen and Hussey, Vincent and Suh, Donny and Gore, Rujuta and López-Gil, Norberto and Jaskulski, Matt and Piña-Miguelsanz, Daniel},
title = {Clinical validation of a novel smartphone application for measuring best corrected visual acuity},
journal = {Journal of Optometry},
year = {2023},
volume = {16},
number = {3},
pages = {206--213},
doi = {10.1016/j.optom.2023.01.001}
}
EUVIMED