Effect of Computer-Aided Designing on the Adaptation and Thickness of Major Connector in Cast Partial Dentures - An In Vitro Study
Indian Journal of Dental Research · 2026-04 · 37 (2) · 208-212
DOI: 10.4103/ijdr.ijdr_543_24 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indian Journal of Dental Research, online erschienen am 28.10.2026. Verfasst von Divyansh Sinha und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chenn…. Hauptthemen laut MEDLINE: Computer-Aided Design, Denture Design, Dental Marginal Adaptation, Denture, Partial, Removable. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
With the recent development of technological aids, computer-aided design/computer-aided manufacturing (CAD/CAM) has enabled clinicians to produce a cast partial denture with lesser time and effort, with reduced laboratory steps. The aim of the study was to evaluate overall fit and thickness of major connectors of conventional versus CAD/CAM removable cast partial denture frameworks. Materials and Methods: A maxillary metal framework was designed for a Kennedy class III Modification I arch. The master cast was scanned and used to compare the fit and accuracy of cast partial denture (CPD) frameworks. There are two groups in the study: Group I used conventional wax up and casting, whereas Group II used digital designing and digital metal laser sintering (DMLS). Framework adaptation and thickness were measured using stereomicroscopy.
Results
Stereomicroscopy revealed discrepancies in the adaptation of the frameworks. Upon comparison, the manually cast frameworks demonstrated significantly better fit than DMLS-fabricated frameworks ( P = 0.000). However, the DMLS frameworks were thinner with a mean of 0.847 mm as compared to their manual counterparts with a mean of 1.167 mm ( P = 0.008).
Conclusion
Adaptation of the cast partial denture framework is paramount in the clinical success of the prosthesis, which showed that manual casting performed better than DMLS. The frameworks demonstrated reduced thickness; however, their inferior fit may presently limit their predictable clinical use.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India.
Zitieren
APA
Sinha, D., Venugopalan, S., & Faiz, N. (2026). Effect of Computer-Aided Designing on the Adaptation and Thickness of Major Connector in Cast Partial Dentures - An In Vitro Study. Indian Journal of Dental Research, 37(2), 208-212. https://doi.org/10.4103/ijdr.ijdr_543_24
Vancouver
Sinha D, Venugopalan S, Faiz N. Effect of Computer-Aided Designing on the Adaptation and Thickness of Major Connector in Cast Partial Dentures - An In Vitro Study. Indian Journal of Dental Research. 2026;37(2):208-212. doi:10.4103/ijdr.ijdr_543_24
BibTeX
@article{Sinha2026,
author = {Sinha, Divyansh and Venugopalan, Suresh and Faiz, Nadhirah},
title = {Effect of Computer-Aided Designing on the Adaptation and Thickness of Major Connector in Cast Partial Dentures - An In Vitro Study},
journal = {Indian Journal of Dental Research},
year = {2026},
volume = {37},
number = {2},
pages = {208--212},
doi = {10.4103/ijdr.ijdr_543_24}
}
EUVIMED