Dimensional stability and fit of additively manufactured removable dies in dental cast resins with different chemical compositions
The Journal of Prosthetic Dentistry · 2025
DOI: 10.1016/j.prosdent.2025.02.045 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Fiona Cornelia Arnold und 6 weiteren Autor:innen. Beteiligte Einrichtung: Dissertation student, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland. Hauptthemen laut MEDLINE: Models, Dental, Denture Design, Denture, Partial, Removable, Dental Prosthesis Design. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Additive manufacturing has enabled the fabrication of removable dies in various resins with different compositions. However, the knowledge on the dimensional stability and fit of removable dies fabricated with different dental cast resins is lacking. PURPOSE: The purpose of this in vitro study was to evaluate the effect of dental cast resin type and storage time on the dimensional stability and fit of AM removable dies throughout a 4-week period. MATERIAL AND METHODS: A typodont model with a prepared right first mandibular molar was digitized with an intraoral scanner (IOS) (CEREC Primescan) to generate a standard tessellation language (STL) file. The STL file was imported into a dental design software program to design a removable die with 10-degree shaft taper angle and a hollow partial arch cast with and without the die. The removable die and hollow partial arch cast without the die STLs were used to additively manufacture 48 removable dies (n=16) and 3 hollow casts (n=1) by using a dental cast resin (DentaMODEL) (AM-DM), a bio-based dental cast resin (FotoDent biobased model) (AM-FD), and a nanographene-reinforced dental cast resin (G-Print) (AM-GP). The same IOS was used to digitize each die and when the die was seated into its respective hollow cast 1 day (T0), 1 week (T1), 2 weeks (T2), 3 weeks (T3), and 4 weeks (T4) after fabrication. All STL files were imported into a metrology-grade 3-dimensional analysis software program (Geomagic Control X). The root mean square (RMS) was used to assess deviations in different die regions (crown, root, base of the root, and overall) over 4 weeks, along with fit evaluation by calculating RMS for the crown portion within the cast and measuring mean distance deviations at 5 points on the die. The generalized linear model analysis and Bonferroni-corrected post hoc tests were used to evaluate the data (α=.05). RESULTS: The dimensional stability of the removable dies was affected by the interaction between resin type and die region and by the interaction between the resin type and time point, while the fit of the dies was impacted by the interaction between resin type and time point (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Dissertation student, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey; and PhD student, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, Univers…
- Assistant Professor, Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.
- Private practice, Ordu Oral and Dental Health Center, Ordu, Turkey.
- Head of Department, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; and External Researcher, Division of Gerodontology and Removable Prosthodon…
- Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of…
Zitieren
APA
Arnold, F. C., Dönmez, M. B., Al-Johani, H., Kahveci, Ç., Schimmel, M., Yilmaz, B., & Çakmak, G. (2025). Dimensional stability and fit of additively manufactured removable dies in dental cast resins with different chemical compositions. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.02.045
Vancouver
Arnold FC, Dönmez MB, Al-Johani H, Kahveci Ç, Schimmel M, Yilmaz B, et al. Dimensional stability and fit of additively manufactured removable dies in dental cast resins with different chemical compositions. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2025.02.045
BibTeX
@article{Arnold2025,
author = {Arnold, Fiona Cornelia and Dönmez, Mustafa Borga and Al-Johani, Hanan and Kahveci, Çiğdem and Schimmel, Martin and Yilmaz, Burak and Çakmak, Gülce},
title = {Dimensional stability and fit of additively manufactured removable dies in dental cast resins with different chemical compositions},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
doi = {10.1016/j.prosdent.2025.02.045}
}
EUVIMED