Proximal Tibial Resection Alone Leads to a Significant Increase in Flexion Gap Size in Tibia-First Robotic-Assisted Posterior-Stabilized Total Knee Arthroplasty
Clinics in Orthopedic Surgery · 2026 · 18 (3) · 449
DOI: 10.4055/cios25302 ↗At a glance
Beobachtungsstudie in Clinics in Orthopedic Surgery, 2026. Written by Khairul Anwar Ayob and 1 co-authors. Institution: The Gold Coast Centre for Bone and Joint Surgery, Palm Beach, Australia. Major MEDLINE topics: Arthroplasty, Replacement, Knee, Tibia, Robotic Surgical Procedures. Cited 1 times so far (Crossref); 36 references. The full text is freely available (open access, CC BY-NC 4.0).
Abstract (original language)
Background
Alignment philosophies in total knee arthroplasty (TKA) have shifted from universal mechanical alignment to patient-specific strategies aiming to optimize soft-tissue balance and improve satisfaction. Robotic-assisted TKAs have enhanced preoperative planning and intraoperative assessments, but the effects of sequential bone cuts on joint gaps remain unclear. This study evaluates whether flexion and extension gaps change after the tibial resection in tibia-first (TF) robotic-assisted posterior-stabilized (PS) TKA.
Methods
A prospective observational study included 82 knees (78 patients) undergoing robotic-assisted TKA with a TF workflow. Gap assessments were recorded pre- and post-proximal tibial bone resection, both after posterior cruciate ligament (PCL) excision, using the Velys robotic system software. Changes in medial and lateral flexion and extension gaps were analyzed as paired measurements and correlated with femoral component modifications.
Results
Removal of the proximal tibial bone cut in isolation led to significant changes in the measured gaps, disproportionately more for the flexion than extension space. Medial and lateral flexion gaps increased by a mean of 2.57 mm and 2.30 mm, respectively, compared to minor changes in mean extension gaps (0.26 mm medially and -0.31 mm laterally) (p < 0.001). These changes influenced component sizing and positioning, with femoral component upsizing or component flexion performed in 70% of cases to balance the flexion and extension gaps.
Conclusions
Proximal tibial bone resection, independent of PCL excision, significantly affects flexion gap size in PS-TKA, often necessitating intraoperative adjustments to femoral component size and position. The TF approach allows surgeons a second chance to optimize ligament balance through femoral component positioning, to achieve their desired balance target. While the clinical benefits of this intraoperative flexibility are intuitive, further research is warranted to establish whether this improves patient clinical outcome and satisfaction.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- The Gold Coast Centre for Bone and Joint Surgery, Palm Beach, Australia.
- National Orthopaedic Centre of Excellence for Research and Learning, Department of Orthopaedic Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
ORCID profiles: Khairul Anwar Ayob, David W Liu
Cite
APA
Ayob, K. A., & Liu, D. W. (2026). Proximal Tibial Resection Alone Leads to a Significant Increase in Flexion Gap Size in Tibia-First Robotic-Assisted Posterior-Stabilized Total Knee Arthroplasty. Clinics in Orthopedic Surgery, 18(3), 449. https://doi.org/10.4055/cios25302
Vancouver
Ayob KA, Liu DW. Proximal Tibial Resection Alone Leads to a Significant Increase in Flexion Gap Size in Tibia-First Robotic-Assisted Posterior-Stabilized Total Knee Arthroplasty. Clinics in Orthopedic Surgery. 2026;18(3):449. doi:10.4055/cios25302
BibTeX
@article{Ayob2026,
author = {Ayob, Khairul Anwar and Liu, David W},
title = {Proximal Tibial Resection Alone Leads to a Significant Increase in Flexion Gap Size in Tibia-First Robotic-Assisted Posterior-Stabilized Total Knee Arthroplasty},
journal = {Clinics in Orthopedic Surgery},
year = {2026},
volume = {18},
number = {3},
pages = {449},
doi = {10.4055/cios25302}
}
EUVIMED