EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High in‐vivo accuracy of a novel robotic‐arm‐assisted system for total knee arthroplasty

Faseeh Zaidi, Craig M Goplen, Connor Fitz-Gerald, Scott M Bolam, Michael Hanlon, Jacob T Munro, Andrew P Monk

Knee Surgery, Sports Traumatology, Arthroscopy · 2025

DOI: 10.1002/ksa.12272 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2025. Verfasst von Faseeh Zaidi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, University of Auckland, Auckland, New Zealand. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Zimmer Biomet.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Robotic‐assisted total knee arthroplasty (TKA) has been shown to improve the accuracy and precision of bony resections and implant position. However, the in vivo accuracy of the full surgical workflow has not been widely reported. The primary objective of this study is to determine the accuracy and precision of a robotic‐arm‐assisted system throughout the intraoperative workflow.

Methods

This was a retrospective cohort study of adult patients who underwent primary TKA with various workflows and alignment targets by three arthroplasty‐trained surgeons with previous experience using the ROSA® Knee System (Zimmer Biomet) over a 3‐month follow‐up period. Accuracy and precision were determined by measuring the difference between various workflow time points, including the final preoperative plan (PP), robot‐validated (RV) resection angle and postoperative radiographs (PR). The absolute mean difference between the measurements determined accuracy, and the standard deviation represented precision. The lateral distal femoral angle, medial proximal tibial angle, femoral flexion angle and tibial slope were measured on postoperative coronal long‐leg radiographs and true short‐leg lateral radiographs.

Results

A total of 77 patients were included in the final analyses. The accuracy for the coronal femoral angle was 1.62 ± 1.11°, 0.75 ± 0.79° and 1.96 ± 1.29° for the differences between PP and PR, PP and RV and RV and PR. The tibial coronal accuracy was 1.44 ± 1.03°, 0.81 ± 0.67° and 1.57 ± 1.14° for PP/PR, PP/RV and RV/PR, respectively. Femoral flexion accuracy was 1.39 ± 1.05°, 0.83 ± 0.59° and 1.81 ± 1.21° for PP/PR, PP/RV and RV/PR, respectively. Tibial slope accuracy was 0.99 ± 0.72°, 1.19 ± 0.87° and 1.63 ± 1.11°, respectively. The proportion of patients within 3° was 93.2%, 95.3%, 97.3% and 94.6% for the distal femur, proximal tibia, femoral flexion and tibial slope angles when the final intraoperative plan was compared to PRs. No patients had a postoperative complication at the final follow‐up.

Conclusions

The ROSA Knee System has acceptable accuracy and precision of coronal and sagittal plane resections with few outliers at various steps throughout the platform's entire workflow in vivo. Level of Evidence Level III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresHumansRetrospective StudiesMaleFemaleAgedMiddle AgedKnee JointWorkflowAged, 80 and overTibia

Stichwörter der Autor:innen

ROSA total knee systemaccuracyrobotic surgerytotal knee arthroplasty

Autor:innen und Institutionen

  • Department of Surgery, University of Auckland, Auckland, New Zealand.
  • Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.
  • Department of Orthopaedic Surgery, Auckland City Hospital, Auckland, New Zealand.
  • Department of Surgery, University of Alberta, Edmonton, Alberta, Canada.

Förderung

  • Zimmer Biomet

Zitieren

APA

Zaidi, F., Goplen, C. M., Fitz-Gerald, C., Bolam, S. M., Hanlon, M., Munro, J. T., & Monk, A. P. (2025). High in‐vivo accuracy of a novel robotic‐arm‐assisted system for total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12272

Vancouver

Zaidi F, Goplen CM, Fitz-Gerald C, Bolam SM, Hanlon M, Munro JT, et al. High in‐vivo accuracy of a novel robotic‐arm‐assisted system for total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy. 2025. doi:10.1002/ksa.12272

BibTeX
@article{Zaidi2025,
  author = {Zaidi, Faseeh and Goplen, Craig M and Fitz-Gerald, Connor and Bolam, Scott M and Hanlon, Michael and Munro, Jacob T and Monk, Andrew P},
  title = {High in‐vivo accuracy of a novel robotic‐arm‐assisted system for total knee arthroplasty},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2025},
  doi = {10.1002/ksa.12272}
}
Kostenlos starten →