EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Evaluation of intaglio surface trueness, wear, and fracture resistance of zirconia crown under simulated mastication: a comparative analysis between subtractive and additive manufacturing

Yong-Kyu Kim iD, Jung-Suk Han iD, Hyung-In Yoon iD

The Journal of Advanced Prosthodontics · 2022 · 14 (2) · 122

DOI: 10.4047/jap.2022.14.2.122 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Advanced Prosthodontics, 2022. Verfasst von Yong-Kyu Kim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Korea Medical Device Development Fund, Seoul National University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This in-vitro analysis aimed to compare the intaglio trueness, the antagonist's wear volume loss, and fracture load of various single-unit zirconia prostheses fabricated by different manufacturing techniques. MATERIALS AND METHODS: Zirconia crowns were prepared into four different groups (n = 14 per group) according to the manufacturing techniques and generations of the materials. The intaglio surface trueness (root-mean-square estimates, RMS) of the crown was measured at the marginal, axial, occlusal, and inner surface areas. Half of the specimens were artificially aged in the chewing simulator with 120,000 cycles, and the antagonist's volume loss after aging was calculated. The fracture load for each crown group was measured before and after hydrothermal aging. The intaglio trueness was evaluated with Welch's ANOVA and the antagonist's volume loss was assessed by the Kruskal-Wallis tests. The effects of manufacturing and aging on the fracture resistance of the tested zirconia crowns were determined by two-way ANOVA. RESULTS: The trueness analysis of the crown intaglio surfaces showed surface deviation (RMS) within 50 µm, regardless of the manufacturing methods (P = .053). After simulated mastication, no significant differences in the volume loss of the antagonists were observed among the zirconia groups (P = .946). The manufacturing methods and simulated chewing had statistically significant effects on the fracture resistance (P < .001). CONCLUSION: The intaglio surface trueness, fracture resistance, and antagonist's wear volume of the additively manufactured 3Y-TZP crown were clinically acceptable, as compared with those of the 4Y- or 5Y-PSZ crowns produced by subtractive milling.

Schlagwörter

Stichwörter der Autor:innen

Additive manufacturingAntagonist wearFracture resistanceIntaglio surface truenessSimulated masticationSubtractive manufacturingZirconia

Autor:innen und Institutionen

  • Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea.

ORCID-Profile: Yong-Kyu Kim, Jung-Suk Han, Hyung-In Yoon

Förderung

  • Korea Medical Device Development Fund
  • Seoul National University

Zitieren

APA

Kim, Y. K., Han, J. S., & Yoon, H. I. (2022). Evaluation of intaglio surface trueness, wear, and fracture resistance of zirconia crown under simulated mastication: a comparative analysis between subtractive and additive manufacturing. The Journal of Advanced Prosthodontics, 14(2), 122. https://doi.org/10.4047/jap.2022.14.2.122

Vancouver

Kim YK, Han JS, Yoon HI. Evaluation of intaglio surface trueness, wear, and fracture resistance of zirconia crown under simulated mastication: a comparative analysis between subtractive and additive manufacturing. The Journal of Advanced Prosthodontics. 2022;14(2):122. doi:10.4047/jap.2022.14.2.122

BibTeX
@article{Kim2022,
  author = {Kim, Yong-Kyu and Han, Jung-Suk and Yoon, Hyung-In},
  title = {Evaluation of intaglio surface trueness, wear, and fracture resistance of zirconia crown under simulated mastication: a comparative analysis between subtractive and additive manufacturing},
  journal = {The Journal of Advanced Prosthodontics},
  year = {2022},
  volume = {14},
  number = {2},
  pages = {122},
  doi = {10.4047/jap.2022.14.2.122}
}
Kostenlos starten →