EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Effect of fluid contamination on reverse torque values in implant-abutment connections under oral conditions

Azam Sadat Mostafavi iD, Maryam Memarian iD, Mohammad Ali Seddigh iD

The Journal of Advanced Prosthodontics · 2021 · 13 (1) · 65

DOI: 10.4047/jap.2021.13.1.65 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Advanced Prosthodontics, 2021. Verfasst von Azam Sadat Mostafavi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Tehran University of Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Implant mechanical complications, including screw loosening, can influence dental implant success. It has been shown that torque values are affected by contamination occurred in implant-abutment (I/A) interface. This study aimed to examine the effects of blood, saliva, fluoride and chlorhexidine contamination on reverse torque values (RTVs) of abutment screws in oral conditions. MATERIALS AND METHODS: 50 fixtures were mounted into the stainless-steel holders and divided into five groups (n = 10). Except control group (NC), fixture screw holes in other groups were contaminated with chlorhexidine (CG), saliva (SG), blood (BG), or fluoride (FG). Abutment screws were tightened with a digital torque meter. I/A assemblies were subjected to thermocycling and cyclic loading. The mean RTVs were recorded and data were analyzed with one-way ANOVA and Tukey test. RESULTS: Except for specimens in SG (20.56 ± 1.33), other specimens in BG (21.11 ± 1.54), CG (22.89 ± 1.1) and FG (24.00 ± 1.12) displayed significantly higher RTVs compared to NC (19.00 ± 1.87). The highest RTVs were detected in CG and FG. CONCLUSION: The obtained data robustly suggest that RTVs were significantly affected by fluid contaminations. Specimens in FG and CG displayed the highest RTVs. Therefore, clinicians should have enough knowledge about probable contaminations in I/A interface in order to manage them during clinical procedure and to inform patients about using oral care products.

Schlagwörter

Stichwörter der Autor:innen

Abutment screw looseningBloodChlorhexidineFluid contaminationFluorideSaliva

Autor:innen und Institutionen

  • Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.

ORCID-Profile: Azam Sadat Mostafavi, Maryam Memarian, Mohammad Ali Seddigh

Förderung

  • Tehran University of Medical Sciences

Zitieren

APA

Mostafavi, A. S., Memarian, M., & Seddigh, M. A. (2021). Effect of fluid contamination on reverse torque values in implant-abutment connections under oral conditions. The Journal of Advanced Prosthodontics, 13(1), 65. https://doi.org/10.4047/jap.2021.13.1.65

Vancouver

Mostafavi AS, Memarian M, Seddigh MA. Effect of fluid contamination on reverse torque values in implant-abutment connections under oral conditions. The Journal of Advanced Prosthodontics. 2021;13(1):65. doi:10.4047/jap.2021.13.1.65

BibTeX
@article{Mostafavi2021,
  author = {Mostafavi, Azam Sadat and Memarian, Maryam and Seddigh, Mohammad Ali},
  title = {Effect of fluid contamination on reverse torque values in implant-abutment connections under oral conditions},
  journal = {The Journal of Advanced Prosthodontics},
  year = {2021},
  volume = {13},
  number = {1},
  pages = {65},
  doi = {10.4047/jap.2021.13.1.65}
}