Fachartikel in der Zeitschrift Polymers, online erschienen am 27.07.2026. Verfasst von Zeynep Irkeç und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthetic Dentistry, Faculty of Dentistry, Lokman Hekim University, Ankara 06510, Turkey. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Abutment screw joint stability is essential for the long-term success of implant-supported restorations. However, the effects of antimicrobial agents on implant–abutment screw mechanics remain unclear. This in vitro study evaluated the effects of chlorhexidine and silicone-based sealing gels on reverse torque values (RTVs) following thermomechanical loading.

Methods

Forty-five Straumann implant analog–abutment assemblies were allocated to three groups (n = 15 per group): untreated control, 2% chlorhexidine gel, and a silicone-based gel (Flow.sil) applied to the abutment screw threads prior to tightening. Cemented standardized monolithic zirconia crowns were subjected to thermomechanical aging (750,000 cycles, 100 N, 2 Hz, 5–55 °C). The mechanical performance of the screw joint was assessed using RTVs, whereas calculated torque loss percentages were reported as a complementary outcome to facilitate the clinical interpretation of the reverse torque findings. Data were analyzed using Shapiro–Wilk and Levene’s tests, one-way analysis of variance (ANOVA), and Tukey’s HSD test (α = 0.05).

Results

Significant differences among groups were observed for post-aging RTVs (p < 0.001). The control group exhibited the highest RTVs (33.03 ± 6.57 Ncm), suggesting the most favorable post-aging reverse torque performance. RTVs were lower in the chlorhexidine (25.29 ± 4.78 Ncm) and Flow.sil (23.16 ± 7.39 Ncm) groups. Although the sealing agents did not differ significantly, chlorhexidine yielded numerically higher RTVs than Flow.sil.

Conclusions

Under the present experimental conditions, direct application of antimicrobial and silicone-based sealing agents to the abutment screw threads was associated with lower RTVs than the untreated control condition. Accordingly, the potential mechanical effects of these materials should be considered when selecting screw-sealing protocols.

Schlagwörter

Stichwörter der Autor:innen

chlorhexidinedental implantsscrew looseningsiliconestorque

Autor:innen und Institutionen

  • Department of Prosthetic Dentistry, Faculty of Dentistry, Lokman Hekim University, Ankara 06510, Turkey.
  • Department of Prosthetic Dentistry, Faculty of Dentistry, Ankara University, Ankara 06100, Turkey.
  • Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara 06100, Turkey.
  • Department of Oral Radiology, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University, Jinan 250012, China.

ORCID-Profile: Zeynep Irkeç, Ayben Şentürk

Zitieren

APA

Irkeç, Z., Şentürk, A., & Orhan, K. (2026). Influence of Antimicrobial Sealing Gels on Reverse Torque Values of Implant–Abutment Screws Following Thermomechanical Loading: A Comparative In Vitro Study. Polymers, 18(15), 1834. https://doi.org/10.3390/polym18151834

Vancouver

Irkeç Z, Şentürk A, Orhan K. Influence of Antimicrobial Sealing Gels on Reverse Torque Values of Implant–Abutment Screws Following Thermomechanical Loading: A Comparative In Vitro Study. Polymers. 2026;18(15):1834. doi:10.3390/polym18151834

BibTeX
@article{Irke2026,
  author = {Irkeç, Zeynep and Şentürk, Ayben and Orhan, Kaan},
  title = {Influence of Antimicrobial Sealing Gels on Reverse Torque Values of Implant–Abutment Screws Following Thermomechanical Loading: A Comparative In Vitro Study},
  journal = {Polymers},
  year = {2026},
  volume = {18},
  number = {15},
  pages = {1834},
  doi = {10.3390/polym18151834}
}
Kostenlos starten →