Fachartikel in der Zeitschrift The Journal of Advanced Prosthodontics, 2020. Verfasst von Sang Yeon Han und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, College of Dentistry, Dankook University, Cheonan, Republic of Korea. Die Arbeit wurde bisher 37-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
PURPOSE: The bond strengths between resin denture teeth with various compositions and denture base resins including conventional and AD/CAM purposed materials were evaluated to find influence of each material. MATERIALS AND METHODS: Cylindrical rods (6.0 mm diameter × 8.0 mm length) prepared from pre-polymerized CAD/CAM denture base resin blocks (PMMA Block-pink; Huge Dental Material, Vipi Block-Pink; Vipi Industria) were bonded to the basal surface of resin teeth from three different companies (VITA MFT®; VITA Zahnfabrik, Endura Posterio®; SHOFU Dental, Duracross Physio®; Nissin Dental Products Inc.) using resin cement (Super-Bond C&B; SUN MEDICAL). As a control group, rods from a conventional heat-polymerizing denture base resin (Vertex™ Rapid Simplified; Vertex-Dental B.V. Co.) were attached to the resin teeth using the conventional flasking and curing method. Furthermore, the effect of air abrasion was studied with the highly cross-linked resin teeth (VITA MFT®) groups. The shear bond strengths were measured, and then the fractured surfaces were examined to analyze the mode of failure. RESULTS: The shear bond strengths of the conventional heat-polymerizing PMMA denture resin group and the CAD/CAM denture base resin groups were similar. Air abrasion to VITA MFT® did not improve shear bond strengths. Interfacial failure was the dominant cause of failure for all specimens. CONCLUSION: Shear bond strengths of CAD/CAM denture base materials and resin denture teeth using resin cement are comparable to those of conventional methods.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, College of Dentistry, Dankook University, Cheonan, Republic of Korea.
- Department of Dental Laboratory Technology, Daejeon Health Institute of Technology, Daejeon, Republic of Korea.
- Department of Prosthododntics, College of Dentistry, Dankook Univeristy, Cheonan, Republic of Korea.
ORCID-Profile: Sang Yeon Han, Yun-Hee Moon, Jonghyuk Lee
Zitieren
APA
Han, S. Y., Moon, Y. H., & Lee, J. (2020). Shear bond strength between CAD/CAM denture base resin and denture artificial teeth when bonded with resin cement. The Journal of Advanced Prosthodontics, 12(5), 251. https://doi.org/10.4047/jap.2020.12.5.251
Vancouver
Han SY, Moon YH, Lee J. Shear bond strength between CAD/CAM denture base resin and denture artificial teeth when bonded with resin cement. The Journal of Advanced Prosthodontics. 2020;12(5):251. doi:10.4047/jap.2020.12.5.251
BibTeX
@article{Han2020,
author = {Han, Sang Yeon and Moon, Yun-Hee and Lee, Jonghyuk},
title = {Shear bond strength between CAD/CAM denture base resin and denture artificial teeth when bonded with resin cement},
journal = {The Journal of Advanced Prosthodontics},
year = {2020},
volume = {12},
number = {5},
pages = {251},
doi = {10.4047/jap.2020.12.5.251}
}
EUVIMED