EUVIMEDDescoperă EUVIMED
Video/AudioVergleichsstudie

Accuracy and Concordance of Agitated Saline Bubble-Enhanced Ultrasound versus Chest Radiography by Internal Jugular Insertion Site

Géssica Sabrine Braga Barbosa, Rayra Gomes Ribeiro, Daniela Del Pilar Via Reque Cortes, Marcelo Paes Menezes Filho, Denise Aparecida Botter, Gabriel Monteiro Gutierrez, Monica Carneiro Sandoval, Igor Smolentzov, Camila Eleutério Rodrigues

Journal of Visualized Experiments · 2026-11-10 · (237)

DOI: 10.3791/72476 ↗

At a glance

Video/Audio in Journal of Visualized Experiments, published online on 2026-11-10. Written by Géssica Sabrine Braga Barbosa and 8 co-authors. Institution: Hospital das Clinicas, Faculdade de Medicina, Universidade de Sao Paulo. Major MEDLINE topics: Jugular Veins, Saline Solution, Radiography, Thoracic, Catheterization, Central Venous.

RezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

Non-tunneled hemodialysis catheters (HDCs) are commonly used to initiate renal replacement therapy in hospitalized patients, especially those with acute kidney injury. HDC malposition is associated with delayed therapy and inadequate dialysis. Agitated saline bubble-enhanced ultrasound (SBUS) has emerged as a method for visualizing catheter position at the time of insertion. This study aimed to analyze the accuracy and concordance of SBUS and chest radiography (CXR) for assessing HDC positioning according to the internal jugular vein (IJV) insertion site. A total of 152 hospitalized patients undergoing IJV catheter insertion were assessed from December 2019 to May 2021. Time from puncture to CXR result, procedure-related complications, blood flow during dialysis, and the accuracy and concordance of SBUS compared with CXR for determining HDC position adequacy were evaluated. The median time between catheter insertion and CXR was 191 min [interquartile range (IQR), 93-288 min], with no difference between insertion sites. The main complication after catheter insertion was arterial puncture (2% overall), with a similar incidence at both sites. Inadequate catheter blood flow was more frequent with left IJV insertion than with right IJV insertion. For right IJV catheters, concordance between SBUS and CXR was high (Gwet's AC1 = 0.95; 95% confidence interval [CI], 0.915-0.992), with an accuracy of 95.6%. For left IJV catheters, concordance was low (Gwet's AC1 = 0.37; 95% CI, -0.21-0.94), with an accuracy of 64.3%. Compared with CXR, SBUS was suitable for assessing catheter placement following right IJV insertion but may be less suitable following left IJV insertion.

Subjects

MeSH terms (MEDLINE)

Jugular VeinsSaline SolutionRadiography, ThoracicCatheterization, Central VenousHumansUltrasonographyRenal DialysisMicrobubblesContrast MediaFemale

Substances

Saline SolutionContrast Media

Authors and institutions

  • Hospital das Clinicas, Faculdade de Medicina, Universidade de Sao Paulo.
  • Hospital das Clinicas, Faculdade de Medicina, Universidade de Sao Paulo; sabrinebraga@usp.br.
  • Faculdade de Medicina de Campos.
  • University of Sao Paulo Institute of Mathematics and Statistics.
  • Nephrology Department, Prince of Wales Clinical School - UNSW Medicine & Health.

Cite

APA

Barbosa, G. S. B., Gomes Ribeiro, R., Via Reque Cortes, D. D. P., Paes Menezes Filho, M., Aparecida Botter, D., Monteiro Gutierrez, G., Carneiro Sandoval, M., Smolentzov, I., & Eleutério Rodrigues, C. (2026). Accuracy and Concordance of Agitated Saline Bubble-Enhanced Ultrasound versus Chest Radiography by Internal Jugular Insertion Site. Journal of Visualized Experiments. https://doi.org/10.3791/72476

Vancouver

Barbosa GSB, Gomes Ribeiro R, Via Reque Cortes DDP, Paes Menezes Filho M, Aparecida Botter D, Monteiro Gutierrez G, et al. Accuracy and Concordance of Agitated Saline Bubble-Enhanced Ultrasound versus Chest Radiography by Internal Jugular Insertion Site. Journal of Visualized Experiments. 2026. doi:10.3791/72476

BibTeX
@article{Barbosa2026,
  author = {Barbosa, Géssica Sabrine Braga and Gomes Ribeiro, Rayra and Via Reque Cortes, Daniela Del Pilar and Paes Menezes Filho, Marcelo and Aparecida Botter, Denise and Monteiro Gutierrez, Gabriel and Carneiro Sandoval, Monica and Smolentzov, Igor and Eleutério Rodrigues, Camila},
  title = {Accuracy and Concordance of Agitated Saline Bubble-Enhanced Ultrasound versus Chest Radiography by Internal Jugular Insertion Site},
  journal = {Journal of Visualized Experiments},
  year = {2026},
  number = {237},
  doi = {10.3791/72476}
}
Start for free →