EUVIMEDEUVIMED entdecken
Crossref

Using central venous pressure waveform to confirm the placement of an internal jugular central venous catheter in the intensive care unit

Charlene Kit Zhen Chua, Maurice Le Guen, Richard Lim, Andrew Udy

Australian Critical Care · 2024

DOI: 10.1016/j.aucc.2023.10.007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Australian Critical Care, 2024. Verfasst von Charlene Kit Zhen Chua und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Intensive Care and Hyperbaric Medicine, Alfred Health, Melbourne, Victoria, Australia. Electronic address: ch.chua@alfred.org.au. Hauptthemen laut MEDLINE: Intensive Care Units, Central Venous Pressure, Catheterization, Central Venous, Jugular Veins. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 9 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: A mobile chest X-ray is traditionally performed to confirm the position of an internal jugular central venous catheter (CVC) after placement in the intensive care unit (ICU). Using chest radiography to confirm CVC position often results in delays in authorising the use of the CVC, requires the deployment of additional human resources, and is costly. OBJECTIVE: This study aimed to determine the feasibility and accuracy of using the central venous pressure (CVP) waveform to confirm the placement of internal jugular CVCs. METHODS: This retrospective study was conducted in a single quaternary ICU over a 6-month period. We included adult patients who had internal jugular CVC inserted and CVP transduced as part of their routine care in the ICU. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CVP waveform analysis in confirming the position of internal jugular CVC relative to chest radiography were calculated. RESULTS: A total of 241 internal jugular CVCs were inserted (in 219 patients, 35.6% female), and the CVP waveform was assessed. In 231 cases, this suggested adequate placement in a central vein, which corresponded with a correct position on subsequent chest X-ray. On six occasions, the CVP waveforms were interpreted as suboptimal; however, on chest X-rays, the CVCs were noted to be in a suitable position (sensitivity: 97.5%). Four suboptimal CVP waveforms were obtained, and they correctly identified CVC malposition on subsequent chest X-ray (specificity: 100%). The average time from CVC insertion to radiological completion was 118 minutes. CONCLUSION: CVP waveform analysis provides a feasible and reliable method for confirming adequate internal jugular CVC position. The use of chest radiography can be limited to cases where suboptimal CVP waveforms are obtained.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intensive Care UnitsCentral Venous PressureCatheterization, Central VenousJugular VeinsRadiography, ThoracicHumansMaleFemaleRetrospective StudiesMiddle AgedFeasibility StudiesAgedAdultCentral Venous CathetersSensitivity and Specificity

Stichwörter der Autor:innen

Central venous catheterCentral venous pressure waveformChest radiographyIntensive care unitQuality improvement

Autor:innen und Institutionen

  • Department of Intensive Care and Hyperbaric Medicine, Alfred Health, Melbourne, Victoria, Australia. Electronic address: ch.chua@alfred.org.au.
  • Department of Intensive Care and Hyperbaric Medicine, Alfred Health, Melbourne, Victoria, Australia.
  • Department of Intensive Care and Hyperbaric Medicine, Alfred Health, Melbourne, Victoria, Australia; The Australian and New Zealand Intensive Care Research Centre, School of Public Health and Preventive Medicine, Monash…

Zitieren

APA

Chua, C. K. Z., Le Guen, M., Lim, R., & Udy, A. (2024). Using central venous pressure waveform to confirm the placement of an internal jugular central venous catheter in the intensive care unit. Australian Critical Care. https://doi.org/10.1016/j.aucc.2023.10.007

Vancouver

Chua CKZ, Le Guen M, Lim R, Udy A. Using central venous pressure waveform to confirm the placement of an internal jugular central venous catheter in the intensive care unit. Australian Critical Care. 2024. doi:10.1016/j.aucc.2023.10.007

BibTeX
@article{Chua2024,
  author = {Chua, Charlene Kit Zhen and Le Guen, Maurice and Lim, Richard and Udy, Andrew},
  title = {Using central venous pressure waveform to confirm the placement of an internal jugular central venous catheter in the intensive care unit},
  journal = {Australian Critical Care},
  year = {2024},
  doi = {10.1016/j.aucc.2023.10.007}
}
Kostenlos starten →