EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Application Value of a Novel Micro-Coil in High-Resolution Imaging of Experimental Mice Based on 3.0 T Clinical MR

Xueke Qiu, Yang Liu, Fajin Lv

Tomography · 2024

DOI: 10.3390/tomography10060064 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tomography, 2024. Verfasst von Xueke Qiu und 2 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing 400016, Ch…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Mice, Inbred C57BL, Phantoms, Imaging, Signal-To-Noise Ratio. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Foundation of State Key Laboratory of Ultrasound in Medicine and Engineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The clinical magnetic resonance scanner (field strength ≤ 3.0 T) has limited efficacy in the high-resolution imaging of experimental mice. This study introduces a novel magnetic resonance micro-coil designed to enhance the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), thereby improving high-resolution imaging in experimental mice using clinical magnetic resonance scanners. Initially, a phantom was utilized to determine the maximum spatial resolution achievable by the novel micro-coil. Subsequently, 12 C57BL/6JGpt mice were included in this study, and the novel micro-coil was employed for their scanning. A clinical flexible coil was selected for comparative analysis. The scanning methodologies for both coils were consistent. The imaging clarity, noise, and artifacts produced by the two coils on mouse tissues and organs were subjectively evaluated, while the SNR and CNR of the brain, spinal cord, and liver were objectively measured. Differences in the images produced by the two coils were compared. The results indicated that the maximum spatial resolution of the novel micro-coil was 0.2 mm. Furthermore, the subjective evaluation of the images obtained using the novel micro-coil was superior to that of the flexible coil (p < 0.05). The SNR and CNR measurements for the brain, spinal cord, and liver using the novel micro-coil were significantly higher than those obtained with the flexible coil (p < 0.001). Our study suggests that the novel micro-coil is highly effective in enhancing the image quality of clinical magnetic resonance scanners in experimental mice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingMice, Inbred C57BLPhantoms, ImagingSignal-To-Noise RatioAnimalsMiceBrainEquipment DesignLiverSpinal CordArtifacts

Stichwörter der Autor:innen

coilexperimental micehigh-resolutionmagnetic resonance imaging

Autor:innen und Institutionen

  • State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing 400016, China.
  • Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China.

Förderung

  • Foundation of State Key Laboratory of Ultrasound in Medicine and Engineering

Zitieren

APA

Qiu, X., Liu, Y., & Lv, F. (2024). Application Value of a Novel Micro-Coil in High-Resolution Imaging of Experimental Mice Based on 3.0 T Clinical MR. Tomography. https://doi.org/10.3390/tomography10060064

Vancouver

Qiu X, Liu Y, Lv F. Application Value of a Novel Micro-Coil in High-Resolution Imaging of Experimental Mice Based on 3.0 T Clinical MR. Tomography. 2024. doi:10.3390/tomography10060064

BibTeX
@article{Qiu2024,
  author = {Qiu, Xueke and Liu, Yang and Lv, Fajin},
  title = {Application Value of a Novel Micro-Coil in High-Resolution Imaging of Experimental Mice Based on 3.0 T Clinical MR},
  journal = {Tomography},
  year = {2024},
  doi = {10.3390/tomography10060064}
}
Kostenlos starten →