EUVIMEDEUVIMED entdecken
Evaluationsstudie

Design and evaluation of a multi‐purpose RF coil for improving regional MR image quality in the mouse brain

Ching-Tang Chen, Kuan-Hung Cho, Ming-Jye Chen, Po-Hsun He, Hsuan-Han Chiang, Ezequiel Farrher, N Jon Shah, Ching-Po Lin, Li-Wei Kuo, Chang-Hoon Choi

Medical Physics · 2025

DOI: 10.1002/mp.70164 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Medical Physics, 2025. Verfasst von Ching-Tang Chen und 9 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, Taiwan. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Radio Waves. Die Arbeit nennt 37 Literaturangaben. Gefördert von: NHRI, NSTC, DAAD.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The RF coil is an essential component which often limits the achievable signal‐to‐noise ratio (SNR) and image quality in MRI. For preclinical applications, a small coil is commonly employed to target specific regions, thereby enhancing the SNR. However, this approach comes at the expense of reduced coverage.

Purpose

This work aimed to assess the performance of a newly developed multi‐purpose RF coil, which is adjustable to superficial or deep region‐focused mode, for imaging the mouse brain using a 3 T MR system.

Methods

This novel design features a surface coil combined with an add‐on, position‐switchable saddle coil, allowing for two configurations: enhanced and extended modes. These modes were arranged to focus more on either the cortical or deeper regions of the brain, respectively. To evaluate the performance, the conventional surface coils with two different sizes were compared by imaging a 3D‐printed phantom and an in vivo mouse brain.

Results

Using the enhanced mode, the multi‐purpose coil presented a higher signal‐to‐noise ratio than the small but frequently used loop coil in both phantom and mouse brain imaging. In the extended mode, we found that the multi‐purpose coil outperformed the large surface coil.

Conclusions

The utilization of different modes could enhance image quality adaptively for both surface and deep regions of interest. We have demonstrated a simple yet novel concept of RF coil design that enhances the regional image quality for mouse brain imaging, offering great potential for preclinical neuroscience applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingBrainRadio WavesAnimalsMiceSignal-To-Noise RatioEquipment DesignPhantoms, Imaging

Stichwörter der Autor:innen

MRIcoilmagnetic resonance imagingmouse brainpreclinical

Autor:innen und Institutionen

  • Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, Taiwan.
  • Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan.
  • Department of Electronic Engineering, National United University, Miaoli, Taiwan.
  • Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich, Juelich, Germany.
  • Institute of Neuroscience and Medicine - 11, Forschungszentrum Juelich, Juelich, Germany.
  • JARA-BRAIN-Translational Medicine, Aachen, Germany.

Förderung

  • NHRI
  • NSTC
  • DAAD
  • Department of Health, Taipei City Government, Taiwan
  • Civilian Foundation of Tri-Service General Hospital
  • Center for Healthy Longevity and Aging Sciences and the Brain Research Center
  • National Yang Ming Chiao Tung University from the Higher Education Sprout Project by the Ministry of Education
  • National Health Research Institutes

Zitieren

APA

Chen, C. T., Cho, K. H., Chen, M. J., He, P. H., Chiang, H. H., Farrher, E., Shah, N. J., Lin, C. P., Kuo, L. W., & Choi, C. H. (2025). Design and evaluation of a multi‐purpose RF coil for improving regional MR image quality in the mouse brain. Medical Physics. https://doi.org/10.1002/mp.70164

Vancouver

Chen CT, Cho KH, Chen MJ, He PH, Chiang HH, Farrher E, et al. Design and evaluation of a multi‐purpose RF coil for improving regional MR image quality in the mouse brain. Medical Physics. 2025. doi:10.1002/mp.70164

BibTeX
@article{Chen2025,
  author = {Chen, Ching-Tang and Cho, Kuan-Hung and Chen, Ming-Jye and He, Po-Hsun and Chiang, Hsuan-Han and Farrher, Ezequiel and Shah, N Jon and Lin, Ching-Po and Kuo, Li-Wei and Choi, Chang-Hoon},
  title = {Design and evaluation of a multi‐purpose RF coil for improving regional MR image quality in the mouse brain},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.70164}
}
Kostenlos starten →