EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

A novel multifrequency‐tuned transceiver array for human‐brain 31 P ‐ MRSI at 7 T

Xin Li iD, Xiao-Hong Zhu iD, Xiao-Liang Zhang, Matt Waks iD, Wei Chen iD

Magnetic Resonance in Medicine · 2025-06 · 93 (6) · 2640-2654

DOI: 10.1002/mrm.30449 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 04.02.2025. Verfasst von Xin Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Center for Magnetic Resonance Research, Radiology Department, University of Minnesota, Minneapolis, Minnesota, USA. Hauptthemen laut MEDLINE: Brain, Magnetic Resonance Imaging. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIH HHS, the Center for Magnetic Resonance Research (CMRR), University of Minnesota, NCI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Phosphorus‐31 ( 31 P) MR spectroscopy imaging (MRSI) at 7 T is a powerful tool for investigating high‐energy phosphate metabolism in human brains with significantly improved signal‐to‐noise ratio (SNR) and spectral resolution. However, this imaging technique requires dual‐frequency radiofrequency coil for performing brain anatomical imaging and B 0 shimming at proton ( 1 H) operation frequency, and 31 P MRSI at lower operation frequency. Herein, we introduce a novel 31 P‐ 1 H dual‐frequency radiofrequency coil design using a double‐tuned and double‐matched (DODO) coil that does not require complex circuitry or two coil layers and exhibits similar imaging performance as to single‐frequency control coils for both 31 P and 1 H imaging operations.

Methods

We constructed an eight‐element 31 P‐ 1 H dual‐frequency DODO transceiver array and compared its performance with a quadrature‐driven dual‐tuned eight‐element 31 P and eight‐element 1 H transverse electromagnetic volume coil for both phantom and in vivo human‐brain 31 P‐MRSI studies at 7 T.

Results

The DODO transceiver array achieved high spatiotemporal resolution 31 P MRSI with 2.5‐cc nominal voxel size and 22‐min scan time covering the entire human brain, showing excellent SNR for mapping cerebral phosphorous metabolites such as phosphocreatine, adenosine triphosphate, and other low‐concentration metabolites. Compared with the transverse electromagnetic volume coil, the DODO array demonstrated large improvements in 31 P‐MRSI SNR in both phantom and human brain studies, with over 5‐fold SNR gain in peripheral regions and over 2‐fold SNR gain in central brain regions.

Conclusion

This simple and cost‐effective array design and excellent performance can greatly benefit human‐brain 31 P‐MRSI applications at 7 T.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrainMagnetic Resonance ImagingHumansMagnetic Resonance SpectroscopyPhantoms, ImagingEquipment DesignSignal-To-Noise RatioPhosphorus Isotopes

Stichwörter der Autor:innen

31P magnetic resonance spectroscopy imaging31P transceiver arraydual‐frequency RF coilhuman brain metabolic imagingultrahigh field

Substanzen

Phosphorus Isotopes

Autor:innen und Institutionen

  • Center for Magnetic Resonance Research, Radiology Department, University of Minnesota, Minneapolis, Minnesota, USA.
  • Department of Biomedical Engineering, Jacobs School of Medicine and Biomedical Sciences, School of Engineering and Applied Sciences, State University of New York at Buffalo, Buffalo, New York, USA.

ORCID-Profile: Xin Li, Xiao-Hong Zhu, Matt Waks, Wei Chen

Förderung

  • NIH HHS
  • the Center for Magnetic Resonance Research (CMRR), University of Minnesota
  • NCI NIH HHS
  • NIBIB NIH HHS
  • NINDS NIH HHS
  • National Institutes of Health

Zitieren

APA

Li, X., Zhu, X. H., Zhang, X. L., Waks, M., & Chen, W. (2025). A novel multifrequency‐tuned transceiver array for human‐brain 31 P ‐ MRSI at 7 T. Magnetic Resonance in Medicine, 93(6), 2640-2654. https://doi.org/10.1002/mrm.30449

Vancouver

Li X, Zhu XH, Zhang XL, Waks M, Chen W. A novel multifrequency‐tuned transceiver array for human‐brain 31 P ‐ MRSI at 7 T. Magnetic Resonance in Medicine. 2025;93(6):2640-2654. doi:10.1002/mrm.30449

BibTeX
@article{Li2025,
  author = {Li, Xin and Zhu, Xiao-Hong and Zhang, Xiao-Liang and Waks, Matt and Chen, Wei},
  title = {A novel multifrequency‐tuned transceiver array for human‐brain 31 P ‐ MRSI at 7 T},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  volume = {93},
  number = {6},
  pages = {2640--2654},
  doi = {10.1002/mrm.30449}
}
Kostenlos starten →