A novel multifrequency‐tuned transceiver array for human‐brain 31 P ‐ MRSI at 7 T
Magnetic Resonance in Medicine · 2025-06 · 93 (6) · 2640-2654
DOI: 10.1002/mrm.30449 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 04.02.2025. Verfasst von Xin Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Center for Magnetic Resonance Research, Radiology Department, University of Minnesota, Minneapolis, Minnesota, USA. Hauptthemen laut MEDLINE: Brain, Magnetic Resonance Imaging. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIH HHS, the Center for Magnetic Resonance Research (CMRR), University of Minnesota, NCI NIH HHS.
Abstract (Originalsprache)
Purpose
Phosphorus‐31 ( 31 P) MR spectroscopy imaging (MRSI) at 7 T is a powerful tool for investigating high‐energy phosphate metabolism in human brains with significantly improved signal‐to‐noise ratio (SNR) and spectral resolution. However, this imaging technique requires dual‐frequency radiofrequency coil for performing brain anatomical imaging and B 0 shimming at proton ( 1 H) operation frequency, and 31 P MRSI at lower operation frequency. Herein, we introduce a novel 31 P‐ 1 H dual‐frequency radiofrequency coil design using a double‐tuned and double‐matched (DODO) coil that does not require complex circuitry or two coil layers and exhibits similar imaging performance as to single‐frequency control coils for both 31 P and 1 H imaging operations.
Methods
We constructed an eight‐element 31 P‐ 1 H dual‐frequency DODO transceiver array and compared its performance with a quadrature‐driven dual‐tuned eight‐element 31 P and eight‐element 1 H transverse electromagnetic volume coil for both phantom and in vivo human‐brain 31 P‐MRSI studies at 7 T.
Results
The DODO transceiver array achieved high spatiotemporal resolution 31 P MRSI with 2.5‐cc nominal voxel size and 22‐min scan time covering the entire human brain, showing excellent SNR for mapping cerebral phosphorous metabolites such as phosphocreatine, adenosine triphosphate, and other low‐concentration metabolites. Compared with the transverse electromagnetic volume coil, the DODO array demonstrated large improvements in 31 P‐MRSI SNR in both phantom and human brain studies, with over 5‐fold SNR gain in peripheral regions and over 2‐fold SNR gain in central brain regions.
Conclusion
This simple and cost‐effective array design and excellent performance can greatly benefit human‐brain 31 P‐MRSI applications at 7 T.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Center for Magnetic Resonance Research, Radiology Department, University of Minnesota, Minneapolis, Minnesota, USA.
- Department of Biomedical Engineering, Jacobs School of Medicine and Biomedical Sciences, School of Engineering and Applied Sciences, State University of New York at Buffalo, Buffalo, New York, USA.
ORCID-Profile: Xin Li, Xiao-Hong Zhu, Matt Waks, Wei Chen
Förderung
- NIH HHS
- the Center for Magnetic Resonance Research (CMRR), University of Minnesota
- NCI NIH HHS
- NIBIB NIH HHS
- NINDS NIH HHS
- National Institutes of Health
Zitieren
APA
Li, X., Zhu, X. H., Zhang, X. L., Waks, M., & Chen, W. (2025). A novel multifrequency‐tuned transceiver array for human‐brain 31 P ‐ MRSI at 7 T. Magnetic Resonance in Medicine, 93(6), 2640-2654. https://doi.org/10.1002/mrm.30449
Vancouver
Li X, Zhu XH, Zhang XL, Waks M, Chen W. A novel multifrequency‐tuned transceiver array for human‐brain 31 P ‐ MRSI at 7 T. Magnetic Resonance in Medicine. 2025;93(6):2640-2654. doi:10.1002/mrm.30449
BibTeX
@article{Li2025,
author = {Li, Xin and Zhu, Xiao-Hong and Zhang, Xiao-Liang and Waks, Matt and Chen, Wei},
title = {A novel multifrequency‐tuned transceiver array for human‐brain 31 P ‐ MRSI at 7 T},
journal = {Magnetic Resonance in Medicine},
year = {2025},
volume = {93},
number = {6},
pages = {2640--2654},
doi = {10.1002/mrm.30449}
}
EUVIMED