Motion-Driven Automatic IMU Orientation Calibration via SO(3) Pattern Alignment
Sensors · 08.07.2026 · 26 (14) · 4342
DOI: 10.3390/s26144342 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 08.07.2026. Verfasst von Anik Sarker und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Virginia Tech, Blacksburg, VA 24060, USA. Hauptthemen laut MEDLINE: Calibration, Walking. Die Arbeit nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: U.S. National Science Foundation, National Science Foundation.
Abstract (Originalsprache)
Calibration of body-worn inertial measurement units (IMUs) is essential for accurate motion estimation, yet sensor orientations may drift over time due to slippage or long-term integration errors. This causes an IMU to gradually lose alignment with the body segment on which it is mounted. In this paper, we develop a novel technique for Automatic Calibration—recovering this alignment during normal motion, without a dedicated calibration step. We implement automatic calibration by formulating it as the alignment of motion-induced orientation distributions on SO(3). When the activity being performed is known (e.g., walking), the distribution of orientations for a correctly calibrated IMU exhibits a characteristic and repeatable pattern on SO(3). Although sensor drift may rotate this distribution into a different orientation, the underlying pattern remains similar. Thus, we calibrate a drifted IMU by aligning its observed orientation distribution to a prior reference distribution obtained from the same activity, either from the same subject at an earlier time or from other subjects. To perform this alignment, we employ a correspondence-free spherical pattern matching method on SO(3) (SO3_SPMC), based on transformed basis vector distributions and spherical cross-correlation. We evaluate the proposed automatic calibration framework with N = 5 people wearing body-worn IMUs during activities of daily living, demonstrating calibration accuracy comparable to supervised single-frame calibration without requiring explicit calibration poses or user intervention. The activities of walking, typing, and using using a computer mouse were best for automatically calibrating a sensor on the wrist.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, Virginia Tech, Blacksburg, VA 24060, USA.
ORCID-Profile: Anik Sarker, Alan T Asbeck
Förderung
- U.S. National Science Foundation
- National Science Foundation
Zitieren
APA
Sarker, A., & Asbeck, A. T. (2026). Motion-Driven Automatic IMU Orientation Calibration via SO(3) Pattern Alignment. Sensors, 26(14), 4342. https://doi.org/10.3390/s26144342
Vancouver
Sarker A, Asbeck AT. Motion-Driven Automatic IMU Orientation Calibration via SO(3) Pattern Alignment. Sensors. 2026;26(14):4342. doi:10.3390/s26144342
BibTeX
@article{Sarker2026,
author = {Sarker, Anik and Asbeck, Alan T},
title = {Motion-Driven Automatic IMU Orientation Calibration via SO(3) Pattern Alignment},
journal = {Sensors},
year = {2026},
volume = {26},
number = {14},
pages = {4342},
doi = {10.3390/s26144342}
}
EUVIMED