Sequence‐agnostic motion‐correction leveraging efficiently calibrated Pilot Tone signals
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.30161 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Yannick Brackenier und 7 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted, Algorithms. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, Engineering and Physical Sciences Research Council, Ministerio de Ciencia e Innovación.
Abstract (Originalsprache)
Purpose
This study leverages externally generated Pilot Tone (PT) signals to perform motion‐corrected brain MRI for sequences with arbitrary k‐space sampling and image contrast. Theory and Methods PT signals are promising external motion sensors due to their cost‐effectiveness, easy workflow, and consistent performance across contrasts and sampling patterns. However, they lack robust calibration pipelines. This work calibrates PT signal to rigid motion parameters acquired during short blocks (˜4 s) of motion calibration (MC) acquisitions, which are short enough to unobstructively fit between acquisitions. MC acquisitions leverage self‐navigated trajectories that enable state‐of‐the‐art motion estimation methods for efficient calibration. To capture the range of patient motion occurring throughout the examination, distributed motion calibration (DMC) uses data acquired from MC scans distributed across the entire examination. After calibration, PT is used to retrospectively motion‐correct sequences with arbitrary k‐space sampling and image contrast. Additionally, a data‐driven calibration refinement is proposed to tailor calibration models to individual acquisitions. In vivo experiments involving 12 healthy volunteers tested the DMC protocol's ability to robustly correct subject motion.
Results
The proposed calibration pipeline produces pose parameters consistent with reference values, even when distributing only six of these approximately 4‐s MC blocks, resulting in a total acquisition time of 22 s. In vivo motion experiments reveal significant () improved motion correction with increased signal to residual ratio for both MPRAGE and SPACE sequences with standard k‐space acquisition, especially when motion is large. Additionally, results highlight the benefits of using a distributed calibration approach.
Conclusions
This study presents a framework for performing motion‐corrected brain MRI in sequences with arbitrary k‐space encoding and contrast, using externally generated PT signals. The DMC protocol is introduced, promoting observation of patient motion occurring throughout the examination and providing a calibration pipeline suitable for clinical deployment. The method's application is demonstrated in standard volumetric MPRAGE and SPACE sequences.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
- Center for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
- Biomedical Image Technologies, ETSI Telecomunicación, Universidad Politécnica de Madrid and CIBER-BNN, ISCIII, Madrid, Spain.
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK.
ORCID-Profile: Yannick Brackenier, Sarah McElroy, Raphael Tomi-Tricot, Shaihan J Malik
Förderung
- Wellcome Trust
- Engineering and Physical Sciences Research Council
- Ministerio de Ciencia e Innovación
Zitieren
APA
Brackenier, Y., Cordero-Grande, L., McElroy, S., Tomi-Tricot, R., Barbaroux, H., Bridgen, P., Malik, S. J., & Hajnal, J. V. (2024). Sequence‐agnostic motion‐correction leveraging efficiently calibrated Pilot Tone signals. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30161
Vancouver
Brackenier Y, Cordero-Grande L, McElroy S, Tomi-Tricot R, Barbaroux H, Bridgen P, et al. Sequence‐agnostic motion‐correction leveraging efficiently calibrated Pilot Tone signals. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30161
BibTeX
@article{Brackenier2024,
author = {Brackenier, Yannick and Cordero-Grande, Lucilio and McElroy, Sarah and Tomi-Tricot, Raphael and Barbaroux, Hugo and Bridgen, Philippa and Malik, Shaihan J and Hajnal, Joseph V},
title = {Sequence‐agnostic motion‐correction leveraging efficiently calibrated Pilot Tone signals},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30161}
}
EUVIMED