EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Modelling Stochastic Sensor Noise via Mask-Conditioned Diffusion for Data Augmentation in Low-SNR LGE-CMR

Sofia Fernandes, Carla Barros iD, Adriano Pinto iD, Vitor H Pereira, Carlos Lima, Carlos A Silva

Sensors · 07.05.2026 · 26 (10) · 2933

DOI: 10.3390/s26102933 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 07.05.2026. Verfasst von Sofia Fernandes und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Industrial Electronics, School of Engineering, University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Late gadolinium enhancement cardiovascular magnetic resonance (LGE-CMR) permits non-invasive quantification of myocardial fibrosis; however, automated scar segmentation remains challenging due to limited expert annotations and reduced image quality caused by acquisition noise and artefacts. We investigate two related questions: (i) whether inversion of a stochastic Gaussian diffusion process can reproduce the texture characteristics of low-signal-to-noise-ratio (SNR) LGE imaging, and (ii) whether the resulting synthetic data can improve automated fibrosis segmentation in annotation-limited settings. To this end, we introduce a mask-conditioned denoising diffusion probabilistic model (DDPM) that synthesises high-fidelity 2D short-axis LGE-CMR slices from three-class label maps (background, myocardium, scar), and we employ these synthetic images for training-set augmentation. The impact of augmentation was assessed using the nnU-Net v2 segmentation framework and benchmarked against exemplar-guided image synthesis with CoCosNet-v2 under identical data partitioning. On a held-out test set trained with 100 real cases, inclusion of 300 diffusion-generated cases increased the scar Dice coefficient from 0.173 to 0.271 (+56.7%), and the scar recall from 0.173 to 0.363, demonstrating enhanced sensitivity to fibrotic lesions. For comparable training budgets, diffusion-based augmentation consistently outperformed GAN-based augmentation, although performance improvements were non-monotonic with respect to the real-to-synthetic data ratio and attenuated as the size of the real dataset increased. A four-axis noise-fidelity analysis (spectral content, signal-dependent variance, short-range spatial correlation, distributional shape) further shows that the DDPM reproduces scanner-specific noise statistics substantially more faithfully than the GAN baseline, providing a mechanistic account for the augmentation gap.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingSignal-To-Noise RatioHumansStochastic ProcessesGadoliniumAlgorithmsImage Processing, Computer-AssistedMyocardiumDiffusionFibrosis

Stichwörter der Autor:innen

LGE-CMRdata augmentationdiffusion modelsmyocardial fibrosissignal reconstructionstochastic noise modelling

Substanzen

Gadolinium

Autor:innen und Institutionen

  • Department of Industrial Electronics, School of Engineering, University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal.
  • CMEMS-UMinho, Department of Industrial Electronics, School of Engineering, University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal.
  • AI4MedImaging Medical Solutions, 4705-002 Braga, Portugal.
  • Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, Campus de Gualtar, 4710-057 Braga, Portugal.
  • LABBELS-Associate Laboratory, Braga, 4710-057 Guimarães, Portugal.

ORCID-Profile: Carla Barros, Adriano Pinto

Zitieren

APA

Fernandes, S., Barros, C., Pinto, A., Pereira, V. H., Lima, C., & Silva, C. A. (2026). Modelling Stochastic Sensor Noise via Mask-Conditioned Diffusion for Data Augmentation in Low-SNR LGE-CMR. Sensors, 26(10), 2933. https://doi.org/10.3390/s26102933

Vancouver

Fernandes S, Barros C, Pinto A, Pereira VH, Lima C, Silva CA. Modelling Stochastic Sensor Noise via Mask-Conditioned Diffusion for Data Augmentation in Low-SNR LGE-CMR. Sensors. 2026;26(10):2933. doi:10.3390/s26102933

BibTeX
@article{Fernandes2026,
  author = {Fernandes, Sofia and Barros, Carla and Pinto, Adriano and Pereira, Vitor H and Lima, Carlos and Silva, Carlos A},
  title = {Modelling Stochastic Sensor Noise via Mask-Conditioned Diffusion for Data Augmentation in Low-SNR LGE-CMR},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {10},
  pages = {2933},
  doi = {10.3390/s26102933}
}
Kostenlos starten →