EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A user independent denoising method for x‐nuclei MRI and MRS

Nichlas Vous Christensen iD, Michael Vaeggemose iD, Nikolaj Bøgh iD, Esben S S Hansen iD, Jonas L Olesen iD, Yaewon Kim iD, Daniel B Vigneron iD, Jeremy W Gordon iD, Sune N Jespersen iD, Christoffer Laustsen iD

Magnetic Resonance in Medicine · 2023

DOI: 10.1002/mrm.29817 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2023. Verfasst von Nichlas Vous Christensen und 9 weiteren Autor:innen. Beteiligte Einrichtung: The MR Research Centre, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, Innovation Fund Denmark, the Lundbeck Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

X‐nuclei (also called non‐proton MRI) MRI and spectroscopy are limited by the intrinsic low SNR as compared to conventional proton imaging. Clinical translation of x‐nuclei examination warrants the need of a robust and versatile tool improving image quality for diagnostic use. In this work, we compare a novel denoising method with fewer inputs to the current state‐of‐the‐art denoising method.

Methods

Denoising approaches were compared on human acquisitions of sodium ( 23 Na) brain, deuterium ( 2 H) brain, carbon ( 13 C) heart and brain, and simulated dynamic hyperpolarized 13 C brain scans, with and without additional noise. The current state‐of‐the‐art denoising method Global‐local higher order singular value decomposition (GL‐HOSVD) was compared to the few‐input method tensor Marchenko‐Pastur principal component analysis (tMPPCA). Noise‐removal was quantified by residual distributions, and statistical analyses evaluated the differences in mean‐square‐error and Bland–Altman analysis to quantify agreement between original and denoised results of noise‐added data.

Results

GL‐HOSVD and tMPPCA showed similar performance for the variety of x‐nuclei data analyzed in this work, with tMPPCA removing ˜5% more noise on average over GL‐HOSVD. The mean ratio between noise‐added and denoising reproducibility coefficients of the Bland–Altman analysis when compared to the original are also similar for the two methods with 3.09 ± 1.03 and 2.83 ± 0.79 for GL‐HOSVD and tMPPCA, respectively.

Conclusion

The strength of tMPPCA lies in the few‐input approach, which generalizes well to different data sources. This makes the use of tMPPCA denoising a robust and versatile tool in x‐nuclei imaging improvements and the preferred denoising method.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingImage Processing, Computer-AssistedHumansBrainSignal-To-Noise RatioAlgorithmsMagnetic Resonance SpectroscopyHeartMyocardiumReproducibility of ResultsPrincipal Component Analysis

Stichwörter der Autor:innen

DenoisingMRIdeuteriumhyperpolarized carbon-13sodium

Autor:innen und Institutionen

  • The MR Research Centre, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
  • GE Healthcare, Brøndby, Denmark.
  • A&E, Gødstrup Hospital, Herning, Denmark.
  • Center of Functionally Integrative Neuroscience (CFIN) and MINDLab, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
  • Department of Radiology and Biomedical Imaging, University of California San Francisco (UCSF), San Francisco, California, USA.

ORCID-Profile: Nichlas Vous Christensen, Michael Vaeggemose, Nikolaj Bøgh, Esben S S Hansen, Jonas L Olesen, Yaewon Kim, Daniel B Vigneron, Jeremy W Gordon, Sune N Jespersen, Christoffer Laustsen

Förderung

  • NIH HHS
  • Innovation Fund Denmark
  • the Lundbeck Foundation
  • Karen Elise Jensen Fonden
  • Lundbeck Foundation
  • National Institutes of Health
  • Innovationsfonden

Zitieren

APA

Christensen, N. V., Vaeggemose, M., Bøgh, N., Hansen, E. S. S., Olesen, J. L., Kim, Y., Vigneron, D. B., Gordon, J. W., Jespersen, S. N., & Laustsen, C. (2023). A user independent denoising method for x‐nuclei MRI and MRS. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29817

Vancouver

Christensen NV, Vaeggemose M, Bøgh N, Hansen ESS, Olesen JL, Kim Y, et al. A user independent denoising method for x‐nuclei MRI and MRS. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29817

BibTeX
@article{Christensen2023,
  author = {Christensen, Nichlas Vous and Vaeggemose, Michael and Bøgh, Nikolaj and Hansen, Esben S S and Olesen, Jonas L and Kim, Yaewon and Vigneron, Daniel B and Gordon, Jeremy W and Jespersen, Sune N and Laustsen, Christoffer},
  title = {A user independent denoising method for x‐nuclei MRI and MRS},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  doi = {10.1002/mrm.29817}
}
Kostenlos starten →