Cross-Scanner Harmonization of AI/DL Accelerated Quantitative Bi-Parametric Prostate MRI
Sensors · 2025
DOI: 10.3390/s25185858 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Dariya Malyarenko und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Michigan Medical School, Ann Arbor, MI 48109, USA. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Magnetic Resonance Imaging, Prostate. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, NIH HHS, University of Michigan Basic Radiologic Sciences.
Abstract (Originalsprache)
Clinical application of AI/DL-aided acquisitions for quantitative bi-parametric (q-bp)MRI requires validation and harmonization across vendor platforms. An AI/DL-accelerated q-bpMRI, including 5-echo T2 and 4-b-value apparent diffusion coefficient (ADC) mapping, was implemented on two 3T clinical scanners by two vendors alongside the qualitative standard-of-care (SOC) MRI protocols for six patients with biopsy-confirmed prostate cancer (PCa). AI/DL versus SOC bpMRI image quality was compared for MR-visible PCa lesions on a 4-point Likert-like scale. Quantitative validation and protocol bias assessment were performed using a multiparametric phantom with reference T2 and diffusion kurtosis values mimicking prostate tissue ranges. Six-minute q-bpMRI achieved acceptable diagnostic quality comparable to the SOC. Better SNR was observed for DL/AI versus SOC ADC with method-dependent distortion susceptibility and resolution enhancement. The measured biases were unaffected by AI/DL reconstruction and related to acquisition protocol parameters: constant for spin-echo T2 (−7 ms to +5 ms) and ADC (4b-fit: −0.37 µm2/ms and 2b-fit: −0.19 µm2/ms), while nonlinear for echo-planar T2 (−37 ms to +14 ms). Measured phantom ADC bias dependence on b-value range was consistent with that observed for PCa lesions. Bias correction harmonized lesion T2 and ADC values across different AI/DL-aided q-bpMRI acquisitions. The developed workflow enables harmonization of AI/DL-accelerated quantitative T2 and ADC mapping in multi-vendor clinical settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, University of Michigan Medical School, Ann Arbor, MI 48109, USA.
- Department of Urology, University of Michigan Medical School, Ann Arbor, MI 48109, USA.
ORCID-Profile: Dariya Malyarenko, Scott D Swanson, Yun Jiang
Förderung
- NCI NIH HHS
- NIH HHS
- University of Michigan Basic Radiologic Sciences
- National Institute of Health
Zitieren
APA
Malyarenko, D., Swanson, S. D., Richardson, J., Lowe, S., O'Connor, J., Jiang, Y., Chahine, R., Wells, S. A., & Chenevert, T. L. (2025). Cross-Scanner Harmonization of AI/DL Accelerated Quantitative Bi-Parametric Prostate MRI. Sensors. https://doi.org/10.3390/s25185858
Vancouver
Malyarenko D, Swanson SD, Richardson J, Lowe S, O'Connor J, Jiang Y, et al. Cross-Scanner Harmonization of AI/DL Accelerated Quantitative Bi-Parametric Prostate MRI. Sensors. 2025. doi:10.3390/s25185858
BibTeX
@article{Malyarenko2025,
author = {Malyarenko, Dariya and Swanson, Scott D and Richardson, Jacob and Lowe, Suzan and O'Connor, James and Jiang, Yun and Chahine, Reve and Wells, Shane A and Chenevert, Thomas L},
title = {Cross-Scanner Harmonization of AI/DL Accelerated Quantitative Bi-Parametric Prostate MRI},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25185858}
}
EUVIMED