EUVIMEDEUVIMED entdecken
Open Access

Application of high‐density 2D receiver coil arrays for improved SNR in prostate MRI

Stephen J Riederer iD, Eric A Borisch iD, Qingshuo Du, Adam T Froemming, Thomas C Hulshizer, Akira Kawashima, Kiaran P McGee, Fraser Robb, Phillip J Rossman, Naoki Takahashi

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30289 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Stephen J Riederer und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Phantoms, Imaging, Prostate, Signal-To-Noise Ratio. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCRR NIH HHS, NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To study if adaptive image receive (AIR) receiver coil elements can be configured into a 2D array with high (>45% by diameter) element‐to‐element overlap, allowing improved SNR at depth (0.7–1.5× element diameter) versus conventional (20%) overlap.

Methods

An anterior array composed of twenty 10‐cm diameter elements with 45% overlap arranged into a 4 × 5 grid and a similar 3 × 7 twenty‐one‐element posterior array were constructed. SNR and g‐factor were measured in a pelvic phantom using the new high‐density (HD) arrays (41 total elements) and compared to vendor AIR‐based arrays (30 total elements) with conventional overlap. T 2 ‐weighted fast‐spin‐echo (T2SE) images acquired using both arrays were compared in 20 subjects. SNR was estimated in vivo. Results were compared blindly by three uroradiologists using a five‐point scale. Images using the HD arrays were also compared to a set of images acquired over a range of acceleration factors ( R = 2.0, 2.5, 3.0) with the conventional arrays.

Results

SNR within the phantom was on average 15% higher for R = 1.0, 1.5, and 2.0 using the HD arrays. Across the 20 subjects SNR within the prostate was 11% higher and assessed radiologically as significantly higher ( p < 0.001) for the HD versus conventional arrays. At all acceleration factors the new HD arrays outperformed the conventional arrays ( p ≤ 0.01), allowing increased R for similar SNR.

Conclusion

AIR elements can be configured into 2D arrays with high (45%) element‐to‐element overlap, consistently providing increased SNR at depth versus arrays with conventional (20%) overlap. The SNR improvement allows increased acceleration in T2SE prostate MRI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingPhantoms, ImagingProstateSignal-To-Noise RatioHumansMaleEquipment DesignProstatic NeoplasmsImage Processing, Computer-AssistedReproducibility of ResultsMiddle Aged

Stichwörter der Autor:innen

AIR coilsMRI receiver coilsprostate cancerthin‐slice MRI

Autor:innen und Institutionen

  • Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
  • Grinnell College, Grinnell, Iowa, USA.
  • Department of Radiology, Mayo Clinic, Phoenix, Arizona, USA.
  • GE HealthCare, Aurora, Ohio, USA.

ORCID-Profile: Stephen J Riederer, Eric A Borisch

Förderung

  • NCRR NIH HHS
  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Riederer, S. J., Borisch, E. A., Du, Q., Froemming, A. T., Hulshizer, T. C., Kawashima, A., McGee, K. P., Robb, F., Rossman, P. J., & Takahashi, N. (2025). Application of high‐density 2D receiver coil arrays for improved SNR in prostate MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30289

Vancouver

Riederer SJ, Borisch EA, Du Q, Froemming AT, Hulshizer TC, Kawashima A, et al. Application of high‐density 2D receiver coil arrays for improved SNR in prostate MRI. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30289

BibTeX
@article{Riederer2025,
  author = {Riederer, Stephen J and Borisch, Eric A and Du, Qingshuo and Froemming, Adam T and Hulshizer, Thomas C and Kawashima, Akira and McGee, Kiaran P and Robb, Fraser and Rossman, Phillip J and Takahashi, Naoki},
  title = {Application of high‐density 2D receiver coil arrays for improved SNR in prostate MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30289}
}
Kostenlos starten →