EUVIMEDExplore EUVIMED
Open access · CC BY 4.0

Emergency Position Recovery Using Forward Kinematics in Robotic Patient Positioning Systems for Radiosurgery

Alaa Saadah iD, Laszlo Fadgyas, Donald Medlin, Jad Saud, Jason Henderson, Tibor Koroknai, Mate Koroknai, David Takacs, Peter Panko, Xiaoran Zheng, Endre Takacs iD, Géza Husi iD

Sensors · 2025

DOI: 10.3390/s25041202 ↗

At a glance

Journal article in Sensors, 2025. Written by Alaa Saadah and 11 co-authors. Institution: Doctoral School of Informatics, University of Debrecen, Kassai útca 26, 4028 Debrecen, Hungary. Major MEDLINE topics: Radiosurgery, Patient Positioning, Robotics, Robotic Surgical Procedures. Cited 1 times so far (Crossref); 29 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Research Development and Innovation, Fund of the Ministry of Innovation and Technology.

AbstractSubjectsBibliographic detailsCiteRelated studies

Abstract (original language)

Precise patient positioning is paramount in radiosurgery to ensure the accurate targeting of tumors while minimizing damage to surrounding healthy tissues. This study focuses on the development and validation of a robust forward kinematics (FK) model for a robotic patient positioning system, specifically designed to handle emergency interruptions such as power loss or emergency stops. The FK model integrates data from high-resolution primary encoders within the actuators and secondary encoders post-load on each axis, providing real-time feedback and ensuring sub-millimeter positional accuracy. The control architecture leverages a dual-loop feedback system to enhance precision and stability during operation and recovery. The simulation and experimental results demonstrate that the FK model, combined with encoder feedback, reliably determines the patient bed’s exact position during interruptions and guides the system’s safe and accurate resumption of treatment. These findings underscore the critical role of FK and encoder integration in improving the safety, reliability, and precision of robotic radiosurgery systems, addressing key challenges in medical robotics for radiation therapy.

Subjects

MeSH terms (MEDLINE)

RadiosurgeryPatient PositioningRoboticsRobotic Surgical ProceduresHumansBiomechanical Phenomena

Author keywords

dual-loop controlemergency interruption handlingforward kinematics (FK)medical roboticsprecision positioningprimary encodersradiation therapyradiosurgeryrobotic patient positioningsecondary encoders

Authors and institutions

  • Doctoral School of Informatics, University of Debrecen, Kassai útca 26, 4028 Debrecen, Hungary.
  • Medical Beam Laboratories, 108 Woodbriar Ct., Greenville, SC 29617, USA.
  • Spinotron Kft, Bethlen u. 11-17, 4028 Debrecen, Hungary.
  • Quiverent LLC, 2801 Wade Hampton Blvd. Ste. 115-301, Taylors, SC 29687, USA.
  • Medikai Innováció Kft., Bethlen u. 11-17, 4028 Debrecen, Hungary.
  • Department of Physics and Astronomy, Clemson University, Clemson, SC 29631, USA.

ORCID profiles: Alaa Saadah, Endre Takacs, Géza Husi

Funding

  • National Research Development and Innovation, Fund of the Ministry of Innovation and Technology

Cite

APA

Saadah, A., Fadgyas, L., Medlin, D., Saud, J., Henderson, J., Koroknai, T., Koroknai, M., Takacs, D., Panko, P., Zheng, X., Takacs, E., & Husi, G. (2025). Emergency Position Recovery Using Forward Kinematics in Robotic Patient Positioning Systems for Radiosurgery. Sensors. https://doi.org/10.3390/s25041202

Vancouver

Saadah A, Fadgyas L, Medlin D, Saud J, Henderson J, Koroknai T, et al. Emergency Position Recovery Using Forward Kinematics in Robotic Patient Positioning Systems for Radiosurgery. Sensors. 2025. doi:10.3390/s25041202

BibTeX
@article{Saadah2025,
  author = {Saadah, Alaa and Fadgyas, Laszlo and Medlin, Donald and Saud, Jad and Henderson, Jason and Koroknai, Tibor and Koroknai, Mate and Takacs, David and Panko, Peter and Zheng, Xiaoran and Takacs, Endre and Husi, Géza},
  title = {Emergency Position Recovery Using Forward Kinematics in Robotic Patient Positioning Systems for Radiosurgery},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25041202}
}
Start for free →