Stereo Bi-Telecentric Phase-Measuring Deflectometry
Sensors · 29.09.2024 · 24 (19) · 6321
DOI: 10.3390/s24196321 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 29.09.2024. Verfasst von Yingmo Wang und 1 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Precision Measuring Technology and Instruments, Laboratory of Micro/Nano Manufacturing Technology, Tianjin University, Tianji…. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Foundation of China.
Abstract (Originalsprache)
Replacing the endocentric lenses in traditional Phase-Measuring Deflectometry (PMD) with bi-telecentric lenses can reduce the number of parameters to be optimized during the calibration process, which can effectively increase both measurement precision and efficiency. Consequently, the low distortion characteristics of bi-telecentric PMD contribute to improved measurement accuracy. However, the calibration of the extrinsic parameters of bi-telecentric lenses requires the help of a micro-positioning stage. Using a micro-positioning stage for the calibration of external parameters can result in an excessively cumbersome and time-consuming calibration process. Thus, this study proposes a holistic and flexible calibration solution for which only one flat mirror in three poses is needed. In order to obtain accurate measurement results, the calibration residuals are utilized to construct the inverse distortion map through bicubic Hermite interpolation in order to obtain accurate anchor positioning result. The calibrated stereo bi-telecentric PMD can achieve 3.5 μm (Peak-to-Valley value) accuracy within 100 mm (Width) × 100 mm (Height) × 200 mm (Depth) domain for various surfaces. This allows the obtaining of reliable measurement results without restricting the placement of the surface under test.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Precision Measuring Technology and Instruments, Laboratory of Micro/Nano Manufacturing Technology, Tianjin University, Tianjin 300072, China.
ORCID-Profile: Fengzhou Fang
Förderung
- National Science Foundation of China
Zitieren
APA
Wang, Y., & Fang, F. (2024). Stereo Bi-Telecentric Phase-Measuring Deflectometry. Sensors, 24(19), 6321. https://doi.org/10.3390/s24196321
Vancouver
Wang Y, Fang F. Stereo Bi-Telecentric Phase-Measuring Deflectometry. Sensors. 2024;24(19):6321. doi:10.3390/s24196321
BibTeX
@article{Wang2024,
author = {Wang, Yingmo and Fang, Fengzhou},
title = {Stereo Bi-Telecentric Phase-Measuring Deflectometry},
journal = {Sensors},
year = {2024},
volume = {24},
number = {19},
pages = {6321},
doi = {10.3390/s24196321}
}
EUVIMED