EUVIMEDEUVIMED entdecken
Crossref

High-accuracy synchronous distortion-compensated stereo phase measuring deflectometry with orthogonal geometric constraints

Yingjing Zhao, Xiaokun Wang, Zhongkai Liu, Bin Liu, Mengxue Cai, Shuangshuang Zhang, Yukun Wang, Donglin Xue, Xuejun Zhang

Optics Express · 20.04.2026 · 34 (8) · 14591

DOI: 10.1364/oe.592217 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 09.04.2026. Verfasst von Yingjing Zhao und 8 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

For applications such as the fabrication and in-situ inspection of reflective optical components, phase measuring deflectometry (PMD) is widely used for surface figure measurement due to its simple setup and large dynamic range. However, as the measurement accuracy advances from the micrometer to the nanometer scale, systematic geometric errors increasingly dominate the measurement deviations and manifest as pronounced low-spatial-frequency figure errors. To address this issue, we propose a high-accuracy synchronous distortion-compensated stereo phase measuring deflectometry (SDC-PMD) system with orthogonal geometric constraints, in which lens distortion is explicitly incorporated into a system-level geometric modeling and parameter estimation framework, stable initial values are established under co-located orthogonal constraints, and a unified nonlinear optimization is performed in the original observation space using reprojection residuals. Numerical simulations demonstrate that the proposed method can significantly suppress the geometric errors of the extrinsic parameters and mirror pose, with the reprojection error converging to the order of 5.6 × 10 −5 pixels. Experimentally, the root-mean-square (RMS) figure error is improved to 0.027 μm for a 70-mm high-precision flat mirror, corresponding to a 74.5% improvement over a classical calibration method, while for spherical mirror testing, the RMS absolute deviation from a Zygo interferometer is 0.007 μm. By preserving the physical consistency and engineering controllability of the pinhole model, the proposed system-level modeling and synchronous compensation suppress geometric biases induced by distortion–extrinsic coupling, thereby improving both the measurement accuracy and engineering applicability of stereo PMD.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhao, Y., Wang, X., Liu, Z., Liu, B., Cai, M., Zhang, S., Wang, Y., Xue, D., & Zhang, X. (2026). High-accuracy synchronous distortion-compensated stereo phase measuring deflectometry with orthogonal geometric constraints. Optics Express, 34(8), 14591. https://doi.org/10.1364/oe.592217

Vancouver

Zhao Y, Wang X, Liu Z, Liu B, Cai M, Zhang S, et al. High-accuracy synchronous distortion-compensated stereo phase measuring deflectometry with orthogonal geometric constraints. Optics Express. 2026;34(8):14591. doi:10.1364/oe.592217

BibTeX
@article{Zhao2026,
  author = {Zhao, Yingjing and Wang, Xiaokun and Liu, Zhongkai and Liu, Bin and Cai, Mengxue and Zhang, Shuangshuang and Wang, Yukun and Xue, Donglin and Zhang, Xuejun},
  title = {High-accuracy synchronous distortion-compensated stereo phase measuring deflectometry with orthogonal geometric constraints},
  journal = {Optics Express},
  year = {2026},
  volume = {34},
  number = {8},
  pages = {14591},
  doi = {10.1364/oe.592217}
}
Kostenlos starten →