EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

A deep brain stimulation–conditioned RF coil for 3T MRI

Nicolas Kutscha iD, Mirsad Mahmutovic iD, Bhumi Bhusal iD, Jasmine Vu iD, Chaimaa Chemlali iD, Sam-Luca J D Hansen iD, Markus W May iD, Susanne Knake iD, Laleh Golestanirad iD, Boris Keil iD

Magnetic Resonance in Medicine · 2025-03 · 93 (3) · 1411-1426

DOI: 10.1002/mrm.30331 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 24.10.2024. Verfasst von Nicolas Kutscha und 9 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Medical Physics and Radiation Protection, Department of Life Science Engineering, TH-Mittelhessen University of Applied Sciences, Giesse…. Hauptthemen laut MEDLINE: Deep Brain Stimulation, Magnetic Resonance Imaging, Phantoms, Imaging, Equipment Design. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 83 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, Hessisches Ministerium für Wissenschaft und Kunst, NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop and test an MRI coil assembly for imaging deep brain stimulation (DBS) at 3 T with a reduced level of local specific absorption rate of RF fields near the implant.

Methods

A mechanical rotatable linearly polarized birdcage transmitter outfitted with a 32‐channel receive array was constructed. The coil performance and image quality were systematically evaluated using bench‐level measurements and imaging performance tests, including SNR maps, array element noise correlation, and acceleration capabilities. Electromagnetic simulations and phantom experiments were performed with clinically relevant DBS device configurations to evaluate the reduction of specific absorption rate and temperature near the implant compared with a circular polarized body coil setup.

Results

The linearly polarized birdcage coil features a block‐shaped low electric field region to be co‐aligned with the implanted DBS lead trajectory, while the close‐fit receive array enables imaging with high SNR and enhanced encoding capabilities.

Conclusion

The 3T coil assembly, consisting of a rotating linear birdcage and a 32‐channel close‐fit receive array, showed DBS‐conditioned imaging technology with substantially reduced heat generation at the DBS implants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep Brain StimulationMagnetic Resonance ImagingPhantoms, ImagingEquipment DesignHumansRadio WavesSignal-To-Noise RatioBrain

Stichwörter der Autor:innen

MRI RF coilMRI safetyactive implantable medical devices (AIMD)deep brain stimulation (DBS)finite element modeling (FEM)specific absorption rate (SAR)

Autor:innen und Institutionen

  • Institute of Medical Physics and Radiation Protection, Department of Life Science Engineering, TH-Mittelhessen University of Applied Sciences, Giessen, Germany.
  • Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.
  • Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois, USA.
  • Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany.
  • High-Field and Hybrid MR Imaging, University Hospital Essen, University Duisburg-Essen, Essen, Germany.
  • Department of Neurology, Philipps-Universität Marburg, Marburg, Germany.

ORCID-Profile: Nicolas Kutscha, Mirsad Mahmutovic, Bhumi Bhusal, Jasmine Vu, Chaimaa Chemlali, Sam-Luca J D Hansen, Markus W May, Susanne Knake, Laleh Golestanirad, Boris Keil

Förderung

  • Deutsche Forschungsgemeinschaft
  • Hessisches Ministerium für Wissenschaft und Kunst
  • NIBIB NIH HHS
  • Common Fund
  • Common Fund for Commodities

Zitieren

APA

Kutscha, N., Mahmutovic, M., Bhusal, B., Vu, J., Chemlali, C., Hansen, S. J. D., May, M. W., Knake, S., Golestanirad, L., & Keil, B. (2025). A deep brain stimulation–conditioned RF coil for 3T MRI. Magnetic Resonance in Medicine, 93(3), 1411-1426. https://doi.org/10.1002/mrm.30331

Vancouver

Kutscha N, Mahmutovic M, Bhusal B, Vu J, Chemlali C, Hansen SJD, et al. A deep brain stimulation–conditioned RF coil for 3T MRI. Magnetic Resonance in Medicine. 2025;93(3):1411-1426. doi:10.1002/mrm.30331

BibTeX
@article{Kutscha2025,
  author = {Kutscha, Nicolas and Mahmutovic, Mirsad and Bhusal, Bhumi and Vu, Jasmine and Chemlali, Chaimaa and Hansen, Sam-Luca J D and May, Markus W and Knake, Susanne and Golestanirad, Laleh and Keil, Boris},
  title = {A deep brain stimulation–conditioned RF coil for 3T MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  volume = {93},
  number = {3},
  pages = {1411--1426},
  doi = {10.1002/mrm.30331}
}
Kostenlos starten →