EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Flexible Chitosan-Based Capacitive Humidity Sensors for Respiratory Monitoring

Miaoxin Pan, Jumei Zhou, Shichen Weng, Xingjian Wu

Sensors · 20.02.2024 · 24 (5) · 1352

DOI: 10.3390/s24051352 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 20.02.2024. Verfasst von Miaoxin Pan und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Maritime and Transportation, Ningbo University, Ningbo 315800, China. Hauptthemen laut MEDLINE: Chitosan. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Zhejiang Provincial Natural Science Foundation, Natural Science Foundation of Zhejiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As one of the most important human health indicators, respiratory status is an important basis for the diagnosis of many diseases. However, the high cost of respiratory monitoring makes its use uncommon. This study introduces a low-cost, wearable, flexible humidity sensor for respiratory monitoring. Solution-processed chitosan (CS) placed on a polyethylene terephthalate substrate was used as the sensing layer. An Arduino circuit board was used to read humidity-sensitive voltage changes. The CS-based sensor demonstrated capacitive humidity sensitivity, whereby the capacitance instantly increased from 10−2 to 30 nF when the environmental humidity changed from 43% to 97%. The capacitance logarithm sensitivity and response voltage change was 35.9 pF/%RH and 0.8 V in the RH range from 56% to 97%. And the voltage variation between inhalation and exhalation was ~0.5 V during normal breathing. A rapid response time of ~0.7 s and a recovery time of ~2 s were achieved during respiration testing. Breathing modes (i.e., normal breathing, rest breathing, deep breathing, and fast breathing) and tonal changes during speech could be clearly distinguished. Therefore, such sensors provide a means for economical and convenient wearable respiratory monitoring, and they have the potential to be used for daily health examinations and professional medical diagnoses.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ChitosanHumansHumidityMonitoring, PhysiologicRespirationExhalation

Stichwörter der Autor:innen

chitosanflexible humidity sensorrespiratory monitoring and decoding

Substanzen

Chitosan

Autor:innen und Institutionen

  • School of Maritime and Transportation, Ningbo University, Ningbo 315800, China.

Förderung

  • Zhejiang Provincial Natural Science Foundation
  • Natural Science Foundation of Zhejiang Province

Zitieren

APA

Pan, M., Zhou, J., Weng, S., & Wu, X. (2024). Flexible Chitosan-Based Capacitive Humidity Sensors for Respiratory Monitoring. Sensors, 24(5), 1352. https://doi.org/10.3390/s24051352

Vancouver

Pan M, Zhou J, Weng S, Wu X. Flexible Chitosan-Based Capacitive Humidity Sensors for Respiratory Monitoring. Sensors. 2024;24(5):1352. doi:10.3390/s24051352

BibTeX
@article{Pan2024,
  author = {Pan, Miaoxin and Zhou, Jumei and Weng, Shichen and Wu, Xingjian},
  title = {Flexible Chitosan-Based Capacitive Humidity Sensors for Respiratory Monitoring},
  journal = {Sensors},
  year = {2024},
  volume = {24},
  number = {5},
  pages = {1352},
  doi = {10.3390/s24051352}
}
Kostenlos starten →