Ultra‐Fast Moisture Sensor for Respiratory Cycle Monitoring and Non‐Contact Sensing Applications
Advanced Materials · 2025-02 · 37 (8)
DOI: 10.1002/adma.202414005 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Materials, online erschienen am 16.01.2025. Verfasst von Suman Mandal und 9 weiteren Autor:innen. Beteiligte Einrichtung: Physical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia. Hauptthemen laut MEDLINE: Humidity, Respiration. Die Arbeit wurde bisher 52-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Department of Science and Technology, Ministry of Science and Technology, India, King Abdullah University of Science and Technology.
Abstract (Originalsprache)
As human‐machine interface hardware advances, better sensors are required to detect signals from different stimuli. Among numerous technologies, humidity sensors are critical for applications across different sectors, including environmental monitoring, food production, agriculture, and healthcare. Current humidity sensors rely on materials that absorb moisture, which can take some time to equilibrate with the surrounding environment, thus slowing their temporal response and limiting their applications. Here, this challenge is tackled by combining a nanogap electrode (NGE) architecture with chicked egg‐derived albumen as the moisture‐absorbing component. The sensors offer inexpensive manufacturing, high responsivity, ultra‐fast response, and selectivity to humidity within a relative humidity range of 10–70% RH. Specifically, the egg albumen‐based sensor showed negligible response to relevant interfering species and remained specific to water moisture with a room‐temperature responsivity of 1.15 × 10 4 . The nm‐short interelectrode distance (circa 20 nm) of the NGE architecture enables fast temporal response, with rise/fall times of 10/28 ms, respectively, making the devices the fastest humidity sensors reported to date based on a biomaterial. By leveraging these features, non‐contact moisture sensing and real‐time respiratory cycle monitoring suitable for diagnosing chronic diseases such as sleep apnea, asthma, and pulmonary disease are demonstrated.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Physical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia.
- Organic Electronics Laboratory, Department of Physics, Indian Institute of Technology Kharagpur, Kharagpur, 721302, India.
- Henry Royce Institute and Photon Science Institute, Department of Electrical and Electronic Engineering, The University of Manchester, Oxford Road, Manchester, M13 9PL, UK.
ORCID-Profile: Suman Mandal, Kalaivanan Loganathan, Hendrik Faber, Abhinav Sharma, Murali Gedda, Dipak Kumar Goswami, Martin Heeney, Thomas D Anthopoulos
Förderung
- Department of Science and Technology, Ministry of Science and Technology, India
- King Abdullah University of Science and Technology
Zitieren
APA
Mandal, S., Mantilla, H. M., Loganathan, K., Faber, H., Sharma, A., Gedda, M., Yengel, E., Goswami, D. K., Heeney, M., & Anthopoulos, T. D. (2025). Ultra‐Fast Moisture Sensor for Respiratory Cycle Monitoring and Non‐Contact Sensing Applications. Advanced Materials, 37(8). https://doi.org/10.1002/adma.202414005
Vancouver
Mandal S, Mantilla HM, Loganathan K, Faber H, Sharma A, Gedda M, et al. Ultra‐Fast Moisture Sensor for Respiratory Cycle Monitoring and Non‐Contact Sensing Applications. Advanced Materials. 2025;37(8). doi:10.1002/adma.202414005
BibTeX
@article{Mandal2025,
author = {Mandal, Suman and Mantilla, Harold Mazo and Loganathan, Kalaivanan and Faber, Hendrik and Sharma, Abhinav and Gedda, Murali and Yengel, Emre and Goswami, Dipak Kumar and Heeney, Martin and Anthopoulos, Thomas D},
title = {Ultra‐Fast Moisture Sensor for Respiratory Cycle Monitoring and Non‐Contact Sensing Applications},
journal = {Advanced Materials},
year = {2025},
volume = {37},
number = {8},
doi = {10.1002/adma.202414005}
}
EUVIMED