One-Step Fabrication of Paper-Based Inkjet-Printed Graphene for Breath Monitor Sensors
Biosensors · 2023
DOI: 10.3390/bios13020209 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2023. Verfasst von Wei Yin Lim und 3 weiteren Autor:innen. Beteiligte Einrichtung: Nano and Micro Devices Laboratory, Electrical and Computer Systems Engineering, School of Engineering and Advanced Engineering Platform, Monash Unive…. Hauptthemen laut MEDLINE: Graphite. Die Arbeit wurde bisher 42-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Monash University Malaysia.
Abstract (Originalsprache)
Irregularities in breathing patterns can be detected using breath monitor sensors, and this help clinicians to predict health disorders ranging from sleep disorders to heart failures. Variations in humidity during the inhalation and exhalation of breath have been utilized as a marker to detect breath patterns, and graphene-based devices are the favored sensing media for relative humidity (RH). In general, most graphene-based RH sensors have been used to explore resistance change as a measurement parameter to calibrate against the RH value, and they are prone to noise interference. Here, we fabricated RH sensors using graphene ink as a sensing medium and printed them in the shape of interdigital electrodes on glossy paper using an office inkjet printer. Further, we investigated the capacitance change in the sensor for the RH changes in the range of 10–70%. It exhibited excellent sensitivity with 0.03 pF/% RH, good stability, and high intraday and interday repeatability, with relative standard deviations of 1.2% and 2.2%, respectively. Finally, the sensor was embedded into a face mask and interfaced with a microcontroller, and capacitance change was measured under three different breathing situations: normal breathing, deep breathing, and coughing. The result show that the dominant frequency for normal breath is 0.22 Hz, for deep breath, it is 0.11 Hz, and there was no significant dominant cough frequency due to persistent coughing and inconsistent patterns. Moreover, the sensor exhibited a short response and recovery time (
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Nano and Micro Devices Laboratory, Electrical and Computer Systems Engineering, School of Engineering and Advanced Engineering Platform, Monash University Malaysia, Bandar Sunway 47500, Malaysia.
- Department of Mechatronics and Biomedical Engineering, Lee Kong Chian Faculty of Engineering and Science (LKCFES), Sungai Long Campus, Universiti Tunku Abdul Rahman, Jalan Sungai Long, Bandar Sungai Long, Kajang 43200,…
ORCID-Profile: Wei Yin Lim, Narayanan Ramakrishnan
Förderung
- Monash University Malaysia
Zitieren
APA
Lim, W. Y., Goh, C. H., Yap, K. Z., & Ramakrishnan, N. (2023). One-Step Fabrication of Paper-Based Inkjet-Printed Graphene for Breath Monitor Sensors. Biosensors. https://doi.org/10.3390/bios13020209
Vancouver
Lim WY, Goh CH, Yap KZ, Ramakrishnan N. One-Step Fabrication of Paper-Based Inkjet-Printed Graphene for Breath Monitor Sensors. Biosensors. 2023. doi:10.3390/bios13020209
BibTeX
@article{Lim2023,
author = {Lim, Wei Yin and Goh, Choon-Hian and Yap, Keenan Zhihong and Ramakrishnan, Narayanan},
title = {One-Step Fabrication of Paper-Based Inkjet-Printed Graphene for Breath Monitor Sensors},
journal = {Biosensors},
year = {2023},
doi = {10.3390/bios13020209}
}
EUVIMED