EUVIMEDEUVIMED entdecken
Crossref

Flexible wearable fiber optic sensor for real-time human breath monitoring based on Fabry-Perot interferometer with agar film

Guoxin Shi, Wenwen Wang, Yingkuan Guo, Jingshun Pan, Dandan Sun, Jie Ma

Optics Express · 2024

DOI: 10.1364/oe.535272 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, 2024. Verfasst von Guoxin Shi und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Fiber Optic Technology, Interferometry, Wearable Electronic Devices, Agar. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Program of Marine Economy Development Special Fund (Six Marine Industries) under Department of Natural Resources of Guangdong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A flexible wearable sensor based on the Fabry-Perot (FP) structure for human breath monitoring is proposed and demonstrated. This sensor is constructed by fusing a single-mode optical fiber to a small section of capillary and coating the end with agar film. In high relative humidity (RH) environments, the agar film absorbs moisture from the air, which leads to a change in the length of the FP cavity to cause a shift in the interference spectrum. The sensor has a sensitivity of 0.95 nm/%RH for testing RH in the range of 60%RH to 85%RH. The temperature sensitivity of the sensor varies nonlinearly from 30°C to 90°C, averaging 0.34 nm/°C over the range of 30°C to 55°C and 0.06 nm/°C over the range of 60°C to 90°C. The temperature and RH crosstalk problems can be solved by using cascaded fiber Bragg grating followed by matrix operations to monitor temperature and RH parameters simultaneously. In addition, the sensor has a fast response time of 0.88 s and a recovery time of 1.17 s for human breathing. The normal and deep breathing of nine subjects are monitored using the sensor, demonstrating that the sensor is able to recognize normal and deep breathing accurately. The success of this sensor proves that it is feasible to develop sensors with good resistance to vibration interference, good repeatability and high stability for human breath monitoring, which is of great significance for research on human breath monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fiber Optic TechnologyInterferometryWearable Electronic DevicesAgarHumansEquipment DesignMonitoring, PhysiologicOptical FibersHumidityTemperatureBreath TestsRespiration

Substanzen

Agar

Förderung

  • National Natural Science Foundation of China
  • Program of Marine Economy Development Special Fund (Six Marine Industries) under Department of Natural Resources of Guangdong Province

Zitieren

APA

Shi, G., Wang, W., Guo, Y., Pan, J., Sun, D., & Ma, J. (2024). Flexible wearable fiber optic sensor for real-time human breath monitoring based on Fabry-Perot interferometer with agar film. Optics Express. https://doi.org/10.1364/oe.535272

Vancouver

Shi G, Wang W, Guo Y, Pan J, Sun D, Ma J. Flexible wearable fiber optic sensor for real-time human breath monitoring based on Fabry-Perot interferometer with agar film. Optics Express. 2024. doi:10.1364/oe.535272

BibTeX
@article{Shi2024,
  author = {Shi, Guoxin and Wang, Wenwen and Guo, Yingkuan and Pan, Jingshun and Sun, Dandan and Ma, Jie},
  title = {Flexible wearable fiber optic sensor for real-time human breath monitoring based on Fabry-Perot interferometer with agar film},
  journal = {Optics Express},
  year = {2024},
  doi = {10.1364/oe.535272}
}
Kostenlos starten →