Finite Element-Based Design of Experiments for the Optimal Geometry of a Ti6Al4V Hip Implant Stem: Influence of Loading Direction

Vinyas, Raviraj Shetty, Gururaj Bolar, Harishkumar Kamat, Jonathan Monteiro, Supriya J P, Amulya Shetty, Adithya Hegde

Prosthesis · 18.11.2026 · 8 (11) · 123

DOI: 10.3390/prosthesis8110123 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Prosthesis, online erschienen am 18.11.2026. Verfasst von Vinyas und 7 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Finite element optimization of hip implant stems is usually performed under a single simplified load, often directed along the neck axis. This study asks whether the geometric parameters governing stem stress change with the idealized static loading direction.

Methods

A Taguchi L27 array of a parametric Ti6Al4V stem (four geometric parameters, three levels each) was analyzed with quadratic tetrahedral elements under 2300 N applied along the neck axis (Case A) and vertically through the femoral head (Case B). The response was the peak von Mises stress outside the potted region and a 12 mm exclusion region at the tied head–trunnion junction. Contributions were quantified by single-factor analysis of variance (ANOVA).

Results

The two loads gave different outcomes. Under neck-axis loading, the peak stress was 74.2–92.8 MPa and neck length explained 100.0% of the variance. Under vertical loading, the peak stress was 218.8–636.8 MPa, neck base radius (58.5%) and neck top radius (29.9%) dominated, and neck length explained 4.7%. The effect of neck length reversed: increasing it from 20 to 30 mm lowered the neck-axis stress by 19.8% but raised the mean vertical stress by 15.4%. The rank correlation between cases was weak (ρ = −0.23).

Conclusions

Within this model and these factor ranges, optimizing under neck-axis loading alone fixes only the neck length and leaves the vertical response undetermined. Designs 12, 24, and 9 gave the best compromise between the two loads. Stem geometry should therefore be optimized under both loading directions.

Zitieren

APA

Vinyas, Shetty, R., Bolar, G., Kamat, H., Monteiro, J., P, S. J., Shetty, A., & Hegde, A. (2026). Finite Element-Based Design of Experiments for the Optimal Geometry of a Ti6Al4V Hip Implant Stem: Influence of Loading Direction. Prosthesis, 8(11), 123. https://doi.org/10.3390/prosthesis8110123

Vancouver

Vinyas, Shetty R, Bolar G, Kamat H, Monteiro J, P SJ, et al. Finite Element-Based Design of Experiments for the Optimal Geometry of a Ti6Al4V Hip Implant Stem: Influence of Loading Direction. Prosthesis. 2026;8(11):123. doi:10.3390/prosthesis8110123

BibTeX
@article{Vinyas2026,
  author = {Vinyas and Shetty, Raviraj and Bolar, Gururaj and Kamat, Harishkumar and Monteiro, Jonathan and P, Supriya J and Shetty, Amulya and Hegde, Adithya},
  title = {Finite Element-Based Design of Experiments for the Optimal Geometry of a Ti6Al4V Hip Implant Stem: Influence of Loading Direction},
  journal = {Prosthesis},
  year = {2026},
  volume = {8},
  number = {11},
  pages = {123},
  doi = {10.3390/prosthesis8110123}
}
Kostenlos starten →