Influence of Scan Path and Operator Experience on the Trueness of Extraoral Complete Denture Digitization with an Intraoral Scanner: An Exploratory In Vitro Study
Prosthesis · 02.11.2026 · 8 (11) · 118
DOI: 10.3390/prosthesis8110118 ↗Kurz gefasst
Fachartikel in der Zeitschrift Prosthesis, online erschienen am 02.11.2026. Verfasst von Kanako Shibuya und 7 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
Background/Objectives: Previous studies on the digitization of complete dentures with intraoral scanners (IOSs) have reported inconsistent effects of scan path, and whether these effects depend on operator experience remains unclear. This exploratory in vitro study investigated the effects of scan path and operator IOS experience on the trueness of extraoral scanning of complete dentures.
Methods
One maxillary and one mandibular complete denture were scanned with a TRIOS 5 IOS using four scan paths: TRIOS denture, TRIOS dentate, rolling, and BOPLM (buccal–occlusal–palatal/lingual–mucosal) methods. Two experienced and two novice dentists repeated each scan path 10 times per arch. Root mean square (RMS) values relative to reference data obtained with a noncontact three-dimensional scanner (FLARE Pro 16M) were analyzed using linear mixed models with operator as a random effect.
Results
In the maxilla, the experience group × scan path interaction was significant (p = 0.034): among novice operators, the rolling method yielded smaller RMS values than the BOPLM method (mean difference = −0.0170 mm, p = 0.001), whereas scan paths did not differ among experienced operators (p = 0.114). No significant effects were found in the mandible. Scanning time did not differ among scan paths.
Conclusions
Among novice operators, the rolling method showed higher trueness than the BOPLM method for maxillary dentures. The effect of scan path may depend on operator experience; however, this exploratory finding requires confirmation with a larger number of operators.
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Shibuya, K., Mukai, T., Yamane, K., Sugiki, R., Tabata, T., Hirayama, M., Watanabe, M., & Furuya, J. (2026). Influence of Scan Path and Operator Experience on the Trueness of Extraoral Complete Denture Digitization with an Intraoral Scanner: An Exploratory In Vitro Study. Prosthesis, 8(11), 118. https://doi.org/10.3390/prosthesis8110118
Vancouver
Shibuya K, Mukai T, Yamane K, Sugiki R, Tabata T, Hirayama M, et al. Influence of Scan Path and Operator Experience on the Trueness of Extraoral Complete Denture Digitization with an Intraoral Scanner: An Exploratory In Vitro Study. Prosthesis. 2026;8(11):118. doi:10.3390/prosthesis8110118
BibTeX
@article{Shibuya2026,
author = {Shibuya, Kanako and Mukai, Tomoko and Yamane, Kunihito and Sugiki, Ryo and Tabata, Tomohiro and Hirayama, Mana and Watanabe, Masataka and Furuya, Junichi},
title = {Influence of Scan Path and Operator Experience on the Trueness of Extraoral Complete Denture Digitization with an Intraoral Scanner: An Exploratory In Vitro Study},
journal = {Prosthesis},
year = {2026},
volume = {8},
number = {11},
pages = {118},
doi = {10.3390/prosthesis8110118}
}
EUVIMED