Effect of splinting scan bodies on the trueness of complete arch digital implant scans with 5 different intraoral scanners
The Journal of Prosthetic Dentistry · 2024-07 · 132 (1) · 204-210
DOI: 10.1016/j.prosdent.2023.06.015 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024-07. Verfasst von Luís Azevedo und 6 weiteren Autor:innen. Beteiligte Einrichtung: PhD candidate, Department of Conservative Dentistry and Orofacial Prostheses, Faculty of Dentistry, Complutense University of Madrid, Madrid, Spain; …. Hauptthemen laut MEDLINE: Dental Implants. Die Arbeit wurde bisher 46-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
STATEMENT OF PROBLEM: The absence of fixed reference points can affect the trueness of complete arch intraoral digital implant scans. The effect of splinting intraoral scan bodies (ISBs) or the inclusion of artificial landmarks (AL) on the trueness of complete arch digital implant scans is still unclear. PURPOSE: The purpose of this study was to analyze the effect of splinting ISBs or the inclusion of AL on the trueness of complete arch digital implant scans with 5 intraoral scanners (IOSs). MATERIAL AND METHODS: Six tissue-level dental implants (Straumann Tissue Level) were placed in an edentulous patient, and the correspondent definitive cast was digitized with a desktop scanner (IScan4D LS3i) to obtain the reference digital cast. Digital scans (n=10) were performed with 5 IOSs: TRIOS 4, Virtuo Vivo, Medit i700, iTero Element 5D, and Cerec Primescan. Three different scanning techniques were evaluated: conventional (cIOSs), splinted (sIOSs), and AL (AL-IOSs). The scan data obtained were imported into a metrology software program and superimposed to the reference digital cast by using a best-fit algorithm. The overall deviations of the positions of the ISBs were evaluated by using the root-mean-square (RMS) error (α=.05). RESULTS: The mean ±standard deviation trueness values for the cIOSs, sIOSs, and AL-IOSs groups were 48 ±8 µm, 53 ±7 µm, and 49 ±11 µm, respectively, with no statistically significant differences (P=.06). Significant differences were found for the IOSs used with each technique (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- PhD candidate, Department of Conservative Dentistry and Orofacial Prostheses, Faculty of Dentistry, Complutense University of Madrid, Madrid, Spain; Researcher, Center for Interdisciplinary Research in Health, Universid…
- Lecturer, Faculty of Dental Medicine, Universidade Católica Portuguesa (UCP), Viseu, Portugal; and Researcher, Center for Interdisciplinary Research in Health, The Catholic University of Portugal (UCP), Viseu, Portugal.
- Assistant, Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland.
- Master Dental Technician, Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland.
- Head, Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland.
- Assistant Professor, Faculty of Dental Medicine, Universidade Católica Portuguesa (UCP), Viseu, Portugal; and Researcher, Center for Interdisciplinary Research in Health, The Catholic University of Portugal (UCP), Viseu…
Zitieren
APA
Azevedo, L., Marques, T., Karasan, D., Fehmer, V., Sailer, I., Correia, A., & Gómez-Polo, M. (2024). Effect of splinting scan bodies on the trueness of complete arch digital implant scans with 5 different intraoral scanners. The Journal of Prosthetic Dentistry, 132(1), 204-210. https://doi.org/10.1016/j.prosdent.2023.06.015
Vancouver
Azevedo L, Marques T, Karasan D, Fehmer V, Sailer I, Correia A, et al. Effect of splinting scan bodies on the trueness of complete arch digital implant scans with 5 different intraoral scanners. The Journal of Prosthetic Dentistry. 2024;132(1):204-210. doi:10.1016/j.prosdent.2023.06.015
BibTeX
@article{Azevedo2024,
author = {Azevedo, Luís and Marques, Tiago and Karasan, Duygu and Fehmer, Vincent and Sailer, Irena and Correia, André and Gómez-Polo, Miguel},
title = {Effect of splinting scan bodies on the trueness of complete arch digital implant scans with 5 different intraoral scanners},
journal = {The Journal of Prosthetic Dentistry},
year = {2024},
volume = {132},
number = {1},
pages = {204--210},
doi = {10.1016/j.prosdent.2023.06.015}
}
EUVIMED