EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC 4.0

Comparison of trueness, time, and number of images among different denture digitization protocols

Kedith Sawangsri iD, Satita Leelaluk, Yuan-Lynn Hsieh, Damian J Lee iD

Journal of Prosthodontics · 2025-04 · 34 (4) · 388-394

DOI: 10.1111/jopr.13967 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Prosthodontics, online erschienen am 29.10.2024. Verfasst von Kedith Sawangsri und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio, USA. Hauptthemen laut MEDLINE: Denture, Complete, Denture Design, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare trueness, time, and number of images of different denture digitization protocols. Materials and Methods Maxillary and mandibular complete prostheses ( n = 10) were fabricated and attached with four fiducial markers. Reference scans were obtained using a laboratory scanner. Test scans were obtained using three different protocols: intraoral scanner (IOS) with manufacturer's scanning pattern (MA), IOS with rolling scanning pattern (RO), and IOS‐ polyvinylsiloxane technique (IOS‐PVS). The scan time and number of images taken were recorded for analysis. Using 3‐dimensional (3D) inspection software (Geomagic control X), corresponding test scans were superimposed to the reference scan using overall best fit. For trueness analysis, the root mean square (RMS) value of the overall best‐fit superimposition was calculated. One‐way ANOVA followed by Games‐Howell and Tukey post‐hoc tests were applied to analyze trueness, scan time, and number of images. Qualitative analysis of trueness was performed using 3D color mapping.

Results

The lowest RMS value was in the mandibular RO protocol (0.10 ±0.01 mm). The highest RMS value was mandibular scans of the IOS‐PVS protocol (1.46 ± 0.09 mm). The longest digitization time was recorded in the maxillary MA group (3.34 ± 0.70 min), while the shortest was in the mandibular RO protocol (2.48 ± 0.56 min). Qualitative analysis revealed that deviation in IOS‐PVS protocol occurred around the border area of the prosthesis.

Conclusion

The denture digitization protocols tested significantly affected trueness, total scanning time, and number of images. Digitizing dentures using the RO protocol improved trueness and reduced scanning time and the number of images.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Denture, CompleteDenture DesignImage Processing, Computer-AssistedHumansImaging, Three-DimensionalComputer-Aided DesignFiducial MarkersTime FactorsPolyvinylsSiloxanesDental Impression TechniqueMandible

Stichwörter der Autor:innen

accuracycomplete prosthesisdigital duplicationlabor timescan pattern

Substanzen

Polyvinylsvinyl polysiloxaneSiloxanes

Autor:innen und Institutionen

  • Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio, USA.
  • Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Massachusetts, USA.

ORCID-Profile: Kedith Sawangsri, Damian J Lee

Zitieren

APA

Sawangsri, K., Leelaluk, S., Hsieh, Y. L., & Lee, D. J. (2025). Comparison of trueness, time, and number of images among different denture digitization protocols. Journal of Prosthodontics, 34(4), 388-394. https://doi.org/10.1111/jopr.13967

Vancouver

Sawangsri K, Leelaluk S, Hsieh YL, Lee DJ. Comparison of trueness, time, and number of images among different denture digitization protocols. Journal of Prosthodontics. 2025;34(4):388-394. doi:10.1111/jopr.13967

BibTeX
@article{Sawangsri2025,
  author = {Sawangsri, Kedith and Leelaluk, Satita and Hsieh, Yuan-Lynn and Lee, Damian J},
  title = {Comparison of trueness, time, and number of images among different denture digitization protocols},
  journal = {Journal of Prosthodontics},
  year = {2025},
  volume = {34},
  number = {4},
  pages = {388--394},
  doi = {10.1111/jopr.13967}
}
Kostenlos starten →