Impact of operator experience, scanning pattern, and arch location on the time and trueness of complete denture digitization using an intraoral scanner
The Journal of Prosthetic Dentistry · 2025-08 · 134 (2) · 462-468
DOI: 10.1016/j.prosdent.2025.03.022 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025-08. Verfasst von Kedith Sawangsri und 7 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Assistant Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio. Hauptthemen laut MEDLINE: Denture, Complete, Computer-Aided Design, Denture Design, Dental Arch. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
STATEMENT OF PROBLEM: The use of intraoral scanners (IOSs) to digitize complete dentures has been widely adopted. However, the impact of operator experience, scanning patterns, and arch location on the accuracy and scanning time of complete dentures digitized with an IOS is unclear. PURPOSE: The purpose of this in vitro study was to investigate the impact of user experience, scanning patterns, and arch location on the trueness and scanning time of complete dentures digitized with an IOS. MATERIAL AND METHODS: One maxillary and 1 mandibular complete denture were fabricated and scanned using a desktop scanner (E4) to be used as the reference scans. Three experienced (Exp) and 3 inexperienced (Inexp) operators performed denture digitization using an IOS (TRIOS 4) with 2 different scanning patterns: the manufacturer's recommended (MA) and the rolling (RO) scan strategy (n=10). The scanning time for each scan was recorded. Using a 3-dimensional (3D) inspection software program (Geomagic Control X), corresponding test scans were compared with the reference scan using overall best-fit alignment to analyze the trueness (root mean square, RMS). Three-way ANOVA followed by the Bonferroni post hoc tests were applied to analyze the effect of user experience, scanning patterns, and arch location on the trueness and scanning time (α=.05). Qualitative analysis of trueness was performed by using 3D color mapping. RESULTS: For the trueness of maxillary denture digitization, the Inexp MA group demonstrated the highest RMS value (0.144 ±0.060 mm), while the Exp MA showed the lowest RMS value (0.118 ±0.019 mm). The trueness of mandibular denture digital duplicates exhibited comparable RMS values, ranging from 0.096 ±0.016 mm to 0.101 ±0.017 mm. Analysis of variance revealed significant effects of both arch location and operator experience on the trueness of denture digitization using an intraoral scanner (IOS) (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Clinical Assistant Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio.
- Resident, Advanced Prosthodontics Program, The Ohio State University College of Dentistry, Columbus, Ohio.
- Resident, Advanced Education in Prosthodontics, School of Dentistry, University of Alabama at Birmingham, Birmingham, Ala.
- Predoctoral, The Ohio State University College of Dentistry, Columbus, Ohio.
- Undergraduate student, The Ohio State University College of Dentistry, Columbus, Ohio.
- Clinical Assistant Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio. Electronic address: nassani.1@osu.edu.
Zitieren
APA
Sawangsri, K., Leelaluk, S., Ellakany, P., Wade, A. B., Eid, H. W., Zaitseva, D., Nassani, L. M., & Hammoudeh, H. S. (2025). Impact of operator experience, scanning pattern, and arch location on the time and trueness of complete denture digitization using an intraoral scanner. The Journal of Prosthetic Dentistry, 134(2), 462-468. https://doi.org/10.1016/j.prosdent.2025.03.022
Vancouver
Sawangsri K, Leelaluk S, Ellakany P, Wade AB, Eid HW, Zaitseva D, et al. Impact of operator experience, scanning pattern, and arch location on the time and trueness of complete denture digitization using an intraoral scanner. The Journal of Prosthetic Dentistry. 2025;134(2):462-468. doi:10.1016/j.prosdent.2025.03.022
BibTeX
@article{Sawangsri2025,
author = {Sawangsri, Kedith and Leelaluk, Satita and Ellakany, Passent and Wade, Adam B and Eid, Hana W and Zaitseva, Daryna and Nassani, Leonardo M and Hammoudeh, Hanin S},
title = {Impact of operator experience, scanning pattern, and arch location on the time and trueness of complete denture digitization using an intraoral scanner},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
volume = {134},
number = {2},
pages = {462--468},
doi = {10.1016/j.prosdent.2025.03.022}
}
EUVIMED